LED Street Light - Explosion Proof - HL102

Explosion proof LED street light for gas zone 2 and dust zone 21 roads, offering 30–480 W, up to 76,800 lm and IP66/IK10 protection.
Download
View all downloads
  • Explosion proof  LED street Light HL102,New-Infinity,Explosion proof  LED street Light
  • Explosion proof  LED street Light HL102,New-Infinity,Explosion proof  LED street Light
  • Explosion proof  LED street Light HL102,New-Infinity,Explosion proof  LED street Light
  • Explosion proof  LED street Light HL102,New-Infinity,Explosion proof  LED street Light

Description

Product Overview

  • Specifying explosion proof LED lighting for a road network starts with the zone, but it ends with the road: the surface a tanker driver sees at two in the morning, the fence line a security patrol walks, the apron a forklift crosses. HL102 is built for that end of the job — an explosion proof LED street light for gas zone 2 and dust zone 21 areas, offered in three body sizes from 30 W to 480 W so one fixture family covers a perimeter road, a plant entrance and a wide loading apron.
  • The work is outdoor. Our linear and high bay fixtures light the halls, the process buildings and the racks; this one lights the routes between them — the road from the gate to the loading gantry, the perimeter track, the pipe-rack crossings and the open yards where vehicles and pedestrians share a surface. Most installations replace high-pressure sodium or metal halide lanterns on the existing pole layout, so the change shows up in running cost and re-lamping frequency rather than in the way the road is driven at night.
  • What separates it from the indoor explosion-proof bodies in the same range is the optical and mounting package: road-oriented distributions instead of a symmetric high-bay pattern, pole and handle mounting, and the highest output in the family for the largest body. Industrial explosion proof lighting is usually bought as a system across a whole site, and this is the piece that keeps the outdoor half of that system as consistent as the indoor half.
  • Because every road on a site is different, the fixture is configured rather than picked off a shelf. Optic, colour temperature, mounting pattern and dimming are chosen per road, and each of those choices changes something visible on the ground at night.
  • Oil and gas extraction and processing — the internal roads between wells and process units, and the routes a fire tender has to take at night.
  • Tank farms, storage terminals and loading areas — the apron where vehicles manoeuvre at the gantry, and the perimeter road running outside the bund.
  • Chemical plants — the roadways between process blocks where the zone 2 boundary reaches out to the road itself; this is the most common setting for industrial explosion proof lighting in a continuous process plant.
  • Mining and mineral processing — haul-road junctions, plant yards and conveyor crossings, where dust and vibration do more damage than weather.
  • Natural gas stations and power plants — access roads, switchyard perimeters and staff parking, inside the same fence but often lit to a different standard than the process area.
  • Grain storage, food production and general manufacturing — external roads serving silos, intake yards and despatch bays, where LED lighting for manufacturing plants has to meet a site-wide standard even outside the building.
  • Spraying and coating operations — routes serving booths, solvent stores and paint kitchens, where the hazardous area extends out into the yard.
  • Ports, jetties and public facilities — quay roads, dock-side yards and vessel approach areas, where explosion proof LED lighting has to cope with salt air as well as hazardous cargo.
Nighttime view of illuminated industrial tank farm and refinery

Explosion Proof Ratings & Markings

MarkingValue
Zone coverageGas zone 2 and dust zone 21
Gas atmosphere, 30–120 W bodiesEx nR IIC T6 Gc
Dust atmosphere, 30–120 W bodiesEx tb IIIC T80 Db
Alternative marking, 30–120 W bodiesEx nR IIC T4 Gc / Ex tb IIIC T130 Db
Gas atmosphere, 130–480 W bodiesEx nR IIC T5 Gc
Dust atmosphere, 130–480 W bodiesEx tb IIIC T95 Db
Alternative marking, 130–480 W bodiesEx nR IIC T4 Gc / Ex tb IIIC T130 Db
Wind and vibrationHousing and bracket specified for pole-mounted wind load and continuous machinery vibration

Safety Design & Build

In explosion proof LED lighting the enclosure, not the light output, is what a hazardous-area reviewer examines first. The fixture keeps its driver, terminals and LED board inside a sealed die-cast ADC12 aluminium body with a PC optical face, so an internal fault is contained rather than allowed to reach the surrounding atmosphere.

IP66 covers dust tightness and protection against high-pressure water jets — the rating that matters when a road is washed down with a bowser or the site sits in a monsoon climate. IK10 covers impact, so a knocked ladder, a thrown stone or a stray forklift tine does not turn into a water leak.

Heat is managed passively. The rear of the housing is finned, and the driver compartment is separated from the optical chamber, so the electronics run cooler and the gasket is not baked brittle by the LED board above it. There are no fans to seize and no filters to change.

Corrosion resistance belongs to the same story. The die-cast body and white aluminium finish are specified for outdoor industrial air, including the salt-laden atmosphere of a coastal terminal and the chemical-laden air around process units. If the site is close to the sea, or handles fertiliser, salt or acid, say so at the enquiry stage — as with any outdoor LED lighting, the finish and the inspection interval are worth agreeing before the first wet season rather than after it.

The fixture is rated from -35 °C, which covers cold-store yards and northern winters. The upper limit depends on the body size, so confirm the figure for the wattage you are ordering where summers are long and hot, or where the luminaire will sit under a canopy with little air movement.

Wind and vibration are taken by the bracket and the housing rather than left to the pole. A pole-mounted luminaire sits at the end of a lever, and on a gantry next to compressors, or beside a road used by heavy trucks, it is the continuous vibration rather than the gust that loosens a low-grade bracket.

Output & Energy Efficiency

  • Start with the surface, not the wattage. The explosion proof LED light that suits a perimeter road is rarely the one that suits a loading apron; match the body to the width of the surface and the height of the pole, and the wattage follows.
  • 30–120 W body: perimeter roads, staff car parks, short access spurs and the tracks between buildings, where poles sit close together and the surface is narrow.
  • 130–240 W body: the general-purpose unit for industrial explosion proof lighting on site roads carrying tankers, flatbeds and forklifts, plant entrances and the long straight runs between process units.
  • 260–480 W body: wide aprons, terminal yards and high-mast positions where a single fixture has to reach across a large area.
  • Colour temperature is a site decision, not a default. 3000 K and 4000 K sit more comfortably on roads that pass housing, offices or a site boundary; 5000 K and 5700 K give the crisp contrast crews want on terminal roads and loading aprons; 6500 K is there for projects whose lighting standard calls for it.
  • Ra > 70 keeps safety markings, vehicle colours and signage readable. Sodium lighting turns a yard into one flat orange sheet, which is exactly what you do not want where people and plant move in the same space.
  • 50,000 hours rated life. On a hazardous site a re-lamp is a permit job with a lift and an isolation, so the saving on LED lighting maintenance is measured in access and paperwork as much as in lamps.
  • One part number covers 50 Hz and 60 Hz supplies and the common commercial voltages, so a project shipping to several countries does not need a different fixture for each site.

Mounting, Aiming & Installation

  1. Choose the distribution before the hardware. Type 2 throws a long, narrow pattern and suits a straight perimeter road or an access route between buildings; Type 3 is the general carriageway optic for site roads of normal width; Type 4 opens up for aprons, loading squares and wide junctions; the 140° option spreads light broadly for short poles and awkward shapes where a directional beam would leave dark corners. Get this wrong and the explosion proof LED light is fine but the road is not.
  2. Decide the mounting pattern. Pole mounting puts the fixture on a road pole at the usual height; handle mounting uses the bracket arm where a pole is not practical — a wall stub, a canopy edge or an existing steel bracket. Send us the pole-top or bracket dimensions with your enquiry and we will confirm the adapter before the fixtures are packed.
  3. Set the aim with the scale, not by eye. The bracket carries an angle scale, so the first setting can be recorded and every later re-aim can return to it. Photograph the scale on the day of installation and file the number with the site lighting drawings.
  4. Terminate the cable properly. The M25×1.5 gland accepts 8–10 mm and 11–14 mm cable; a gland closed onto an undersized cable, or taped up to make the diameter, is the most common reason a sound fixture fails a site inspection. Fit the gland to the jacket, tighten it, and check the seal before the pole goes up.
  5. Walk the road at night before sign-off. Check for glare into adjacent property, dark patches between poles, and whether the aiming matches the drawings. Ten minutes at handover catches more than a daylight session with a meter.
  6. Record what was fitted. Note the optic type, wattage, colour temperature and bracket angle for each pole. When a fixture is replaced in two years, the replacement matches the road instead of being aimed from scratch.
  7. Certified for gas zone 2 and dust zone 21, with the marking band matched to the fixture you order rather than one certificate stretched across the whole range.
  8. A high-efficacy light engine on a constant-current TOMCARLINE driver, so the running cost stays low on roads that are lit every night of the year.
  9. IP66 and IK10 together: dust-tight, resistant to high-pressure water jets, and able to take a heavy impact without the seal giving way.
  10. Three road distributions plus a 140° option, so the beam is chosen for the road instead of the road being made to fit a symmetric beam.
  11. A bracket with an angle scale, which turns aiming from a guess into a setting that can be recorded and repeated after service.
  12. Supplied as complete, road-ready explosion proof LED light fixtures — housing, bracket, gland and driver in one carton, not a bare luminaire that still needs parts on site.
  13. One bracket and gland arrangement across the range, so the aiming procedure learned on the first pole applies to every pole on the site.

Product Specifications

ParameterValue
Model numberHL102-120W / HL102-240W / HL102-480W
Power30–120 W / 130–240 W / 260–480 W
Dimensions, handle mounting328.4 × 324 × 65.3 / 328.4 × 364 × 65.3 / 658 × 350 × 77.3 mm
Dimensions, pole mounting298 × 450 × 79.5 / 298 × 490 × 79.5 mm; to be confirmed for the 260–480 W body
Luminous efficacy150 ± 10 lm/W
Luminous flux (±10%)4,200–19,200 / 18,200–38,400 / 36,400–76,800 lm
Colour temperature3000 K, 4000 K, 5000 K, 5700 K, 6500 K
Colour rendering indexRa > 70
Beam angleType 2 / Type 3 / Type 4 / 140°
Ingress and impact protectionIP66, IK10
DriverTOMCARLINE, constant current (CC)
Input voltage and frequencyAC 120–277 V, 47–63 Hz
Power factor> 0.9
Luminaire net weight3.4 kg / 4 kg / 9.2 kg

Dimming Interface

As standard this explosion proof LED lighting fixture is supplied non-dimmable. A 1–10 V dimming interface is available as an optional accessory, and on a hazardous site that option is usually worth taking: the road is rarely busy all night, but it can never go dark.

The interface takes a standard 1–10 V control signal from the site lighting controller or building management system and scales the output accordingly. In practice that means part-night dimming after the last shift and the delivery curfew, timed steps that bring the road back up before the morning changeover, or manual override from a control panel while a night operation is running.

Two practical points decide whether it works. The first is the controller: confirm that the dimming signal your system produces is 1–10 V and that it can be run to each pole. The second is the cable — dimming needs a control pair in addition to the supply, and pulling that pair before the trench is backfilled costs a fraction of adding it later.

Dimming is an energy decision, but on a terminal road it is also a safety one. Dropping output to a level that still keeps walkways, kerbs and vehicle routes legible is very different from switching a section off, and that is the difference between a scheme that saves money and one that creates an incident.

Ordering & Packing

  1. Fix the classification first. Industrial explosion proof lighting is specified from the area classification outwards, so confirm the zone, gas group and temperature class your assessment calls for and send them with the road layout.
  2. Choose body, optic, colour temperature and mounting as one decision. Those four make the part number, and changing one later usually means a different carton rather than a different label. If the layout is still open, send the road width, pole height and spacing and we will confirm what the design needs.
  3. Agree the commercial terms with your sales contact. Minimum quantity, price, lead time, payment terms and the delivery point are quoted per project rather than listed as a shelf price, which is normal for LED lighting suppliers working on hazardous-area sites.
  4. Plan for the cartons. Each fixture ships one piece per carton: gross weights are 4.0 kg, 4.6 kg and 10.4 kg from the smallest size to the largest, with export cartons of 38.2 × 35.0 × 14.4 cm for the two shorter sizes and 73 × 42.2 × 15.4 cm for the long one. The 10.4 kg carton is a two-person lift — say where it will be offloaded.
  5. Note the warranty and keep the installation record. The fixture carries a 5-year warranty, and the per-pole record of optic, wattage, colour temperature and bracket angle is what makes a replacement straightforward years later.
  6. Agree the documentation. Tell us the standard your project is measured against and we will confirm what ships with the order. As LED street lighting manufacturers working with hazardous-area projects, we can supply marking details and dimensions in a form your consultant can file directly — useful when explosion proof LED light fixtures are going into a live plant with a fixed installation window.
  7. Build the routine around two visits a year rather than a re-lamp programme: a walk-round at your normal outdoor lighting inspection, and a closer check before storm season, when the bracket bolts and the cable gland get the most attention.
  8. At each visit, look at five things on the pole: the optical face, the gland where the cable enters, the bracket bolts, the condition of the seal after any knock, and whether the marking label is still clean and legible. A hazardous-area auditor reads that label on the fixture, not the datasheet in the office, so a painted-over or faded label is worth replacing.
  9. The driver is the part that normally needs swapping. Hold one TOMCARLINE constant-current driver per body size, plus a spare gland and bracket, and scale the holding to the number of poles of each size rather than to the total fixture count.
  10. Keep one line per pole in the site lighting file: body size, optic type, colour temperature, bracket angle and installation date. That record is what keeps a warranty discussion, a like-for-like replacement across a run of explosion proof LED light fixtures, or a change of maintenance team straightforward.
  11. Most industrial explosion proof lighting is installed in stages while the plant keeps running, so phase the rollout by road function rather than by wattage. Put the 130–240 W body on the main route and the gate first, add the 30–120 W body for spurs and car parks, and leave the 260–480 W body for the aprons and high-mast positions.
  12. Carry the first phase forward. Once the optic, colour temperature and bracket angle are fixed for a road class, quote every later phase against that same configuration, so the aiming procedure learned on the first poles applies to the rest and the spares profile does not grow phase by phase.
  13. Book the lift, the isolation and the delivery per area rather than per fixture. A phase that arrives as one carton set for one stretch of road is commissioned in a single visit, and the next phase can be configured from the previous record instead of a fresh night survey.

Testing & Compliance

Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.

FAQ

Can this fixture be fitted to the poles and brackets we already have?

The range is offered with pole mounting and with handle mounting, and the bracket carries an angle scale so the new fixture can be set to the same aim as the lantern it replaces. Send the pole-top diameter, the bracket height and the weight of the existing lantern when you enquire — poles vary far more than fixture catalogues suggest, and confirming an adapter before packing is cheaper than discovering a mismatch on the day the lift is booked. That is standard practice among LED street lighting manufacturers supplying zone-rated road fixtures: the pole detail is settled before the order leaves.

Which temperature class do we need — T4, T5 or T6?

The class in the marking describes the highest surface temperature the fixture can present to the surrounding atmosphere, and the correct one comes from your area classification rather than from the fixture. The 30–120 W bodies carry T6 gas and T80 dust markings with an alternative T4/T130 version; the 130–480 W bodies carry T5 gas and T95 dust with the same alternative. Tell us the gas group and temperature class your assessment specifies and we will confirm which version of the explosion proof LED light to supply for that road.

How many fixtures will a road need?

It comes down to road width, mounting height, pole spacing and the optic. Send a simple layout — road width, pole positions, mounting height and the light level your site standard asks for — and we will come back with a spacing proposal and the wattage that meets it. A Type 2 optic on a long straight run normally needs fewer, more widely spaced poles than a Type 4 on the same road, because it throws the light along the road rather than across it. The same exercise applies to LED lighting for manufacturing plants, where the yard and the access road are often held to the same standard as the building perimeter.

What maintenance does the fixture need?

Inspection rather than servicing. Wipe the optical face with a soft cloth and clean water at the site's normal lighting-inspection interval, check the gland and the bracket bolts at the same time — especially after storm season — and look at the seal after any impact. The housing is finned and passive, so there are no fans or filters to change on these explosion proof LED light fixtures. The driver is a replaceable constant-current unit and is the first thing to check if a pole goes dark, which is why the per-pole configuration record is worth keeping.

If we light the site in stages, which body should we start with?

Start with the 130–240 W body on the main route and the plant entrance, add the 30–120 W body for spurs, car parks and short access roads, and hold the 260–480 W body for the aprons and high-mast positions. All three share the same driver family and the same optic options, so a phased rollout keeps one spares profile and one aiming procedure across the site. Give us the phase plan and the later stages can be configured to match the first instead of being re-specified — the usual headache when LED street lighting manufacturers change between phases of a long project.