Explosion Proof Flood Light - Industrial Explosion Proof Lighting
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light

LED Flood Light - Explosion Proof - HL101

Explosion proof LED flood light, 50–200 W, 140 ±10 lm/W, IP66/IK10, Class 17 wind resistance and 1–10 V dimming, with bracket or pole mounting.
Download
View all downloads
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light
  • Hazardous area explosion proof LED light HL101,New-Infinity,Hazardous area explosion proof LED light

Description

Product Overview

This is a fixed explosion proof LED light fixture built for sites where an ordinary floodlight is not allowed. Four models run from 50 W to 200 W and deliver 7,000 to 28,000 lumens, so one product covers a walkway between process units, a truck loading bay and the perimeter of a tank farm without switching to a different fixture family.

The body is a square, thick-walled casting with a U-shaped bracket on the sides and a handle on top. A tempered glass front protects a shaped lens and the LED array behind it, and a fin bank on the rear carries heat away from the driver before it reaches the electronics. The finish is a rust-red powder coat — practical as much as visual, because the fixture stays easy to pick out against grey structural steel when someone is aiming it from below.

Most of these are bought to replace HID or first-generation LED floods that have turned into a maintenance item. The old units needed lamp and ballast changes on a cycle, drew considerably more power for the same lit result, and often could not be re-aimed without a second person on the mast. This one is dimmable, driver-controlled, and can be carried and aimed by one technician using the handle.

Hazardous-Area Construction & Approval

  • One sealed assembly — the body, bolted front bezel, rear cover and cable entries work together as a single sealed unit. That construction is the basis of the explosion-proof rating and the reason this LED explosion proof light can go where a standard flood cannot.
  • Check the label against your area classification — send us the zone, division or gas group your site is classified under and we will confirm the rating printed on the fixture label before the order is released. It takes a minute and it prevents a rejected installation.
  • Thick-walled cast body — the housing is cast rather than folded from sheet metal, and the bolted front and rear faces hold their seal through years of heating and cooling cycles.
  • Finned rear housing — the heat sink sits directly behind the LED array and the driver, moving heat out of the enclosure instead of letting it collect around the electronics.
  • Tempered glass over a shaped lens — the glass takes the front impact while the lens underneath sets the beam pattern, so the optical surface is shielded from grit and washdown spray.
  • Cable glands as part of the seal — supply and control cables enter through glands built into the assembly, which is exactly where water ingress starts on most outdoor fixtures.
  • Powder-coated body — the coating is applied over the prepared casting, giving a hard, corrosion-resistant skin that also keeps the fixture visible against plant steelwork.
  • IP66 and IK10 in the same housing — protection against strong water jets and against heavy impact, a combination that suits washdown bays, materials handling areas and sites where tools get dropped. These explosion proof LED lighting fixtures are normally installed at 4–8 m on structural steel or masts.

High Efficiency & Energy Savings

The practical result is that a 100 W unit puts out around 14,000 lumens, where the HID flood it replaces would have needed a much larger electrical load for comparable light on the ground. The driver decides whether that figure survives five years on site. These fixtures use a TOMCARLINE constant-current driver running at a power factor above 0.9 from 47–63 Hz. Constant current holds the LED steady as the supply moves, which is what keeps output even on a plant where voltage sags whenever a large motor starts. Dimming is where a lighting budget actually changes. A 1–10 V control signal lets the site reduce output during quiet periods instead of switching whole circuits on and off, and because the driver handles the reduction, the light dims evenly rather than shifting colour as it comes down. On an industrial explosion proof LED lighting project, that is the difference between a fixed lighting load and one that follows the shift pattern. Rated life is 50,000 hours. On a two-shift schedule that is a service interval measured in years, which is why these tend to be specified as a planned replacement rather than bought lamp by lamp.

Adjustable Handle & Beam Aiming

The handle sounds like a small detail until you are the person on the mast. A 200 W unit weighs around 15.5 kg, and holding that at arm's length while you line up bracket bolts is how explosion proof LED light fixtures get dropped or end up aimed at the wrong spot. The handle gives a balanced grip on the body, so the fixture can be carried up, held in the target direction and kept there while the bracket bolts are tightened.

The U-bracket pivots at both sides of the housing, so the aiming angle is independent of how the bracket is fixed to the wall, the steel or the pole adaptor. Set the angle, tighten the pivot bolts, and this explosion proof LED light fixture stays where it was pointed instead of drifting as the bracket settles.

Beam choice matters as much as aim. Three optics are available: 30° for long, narrow throws such as a walkway running between process units or the face of a tall tank; 60° for general area lighting over manifolds, loading arms and equipment skids; 90° for wide, close-range coverage such as a compressor house floor or the underside of a platform.

The rule of thumb is mounting height against spread. High mounting with a narrow optic gives reach; low mounting with a wide optic avoids a bright pool under the fixture and a dark ring around it. Where a site needs both, order the same body in two beam versions and aim each position on its own — that is how most LED explosion-proof lighting layouts get resolved without adding a second product to the schedule.

Mounting, Wiring & Installation

  1. Confirm the fixing point and the mounting type before anything goes up — bracket type for structural steel or wall, pole type where a mast or pole adaptor is used. Mixing the two on one site is the most common reason explosion proof LED light fixtures come back for a different bracket.
  2. Check the supply against the driver version ordered.
  3. Isolate the circuit, bring the supply cable in through the gland, and terminate earth first, then neutral and live.
  4. Set the beam direction using the handle before the final tightening. Aim from a position where you can see the lit surface, not from directly underneath the fixture.
  5. Tighten the pivot bolts on the U-bracket and check that the gland and the front bezel are fully seated. On these explosion proof LED lighting fixtures the seal is what the IP66 rating rests on, so a bezel that is not fully home is worth catching now rather than at the next washdown.
  6. If dimming is used, connect the 1–10 V control pair and confirm the response at the controller before the circuit is handed over.
  7. Record the beam angle, colour temperature and dimming setting for each position, so the next maintenance visit re-aims to the same target.

Applications

  • Oil and gas extraction and processing — wellheads, manifolds, separator decks and process skids, where the fixture is aimed across equipment rather than down a road. - Storage, transport and loading areas — tank farms, truck and rail loading bays and jetty heads. A 60° or 90° unit on a pole covers the working area without throwing glare into a cab. - Mining and mineral processing — crusher houses, conveyor transfer points and wash bays, where dust and vibration never stop and the LED explosion-proof lighting has to keep working through both. - Natural gas stations and power plants — compressor bays, switchyard walkways and turbine hall access routes. - Grain storage and food production — silos, intake pits, milling floors and packing halls that get washed down between runs. - Spraying and coating operations — booths, mixing rooms and drying areas, where the atmosphere itself is the reason the fitting has to be an LED explosion proof light in the first place. - Pharmaceutical and hazardous materials warehousing — racking aisles, drum stores and dispatch docks, where the classification follows the goods being stored. - Public facilities and vessels — plant perimeter lighting, dock quays, and deck or hold lighting on working vessels. In an industrial explosion proof lighting scheme this is often the fixture that covers the outside of the process area as well as the inside.
Nighttime refinery and offshore oil platform facilities

Product Specifications

Efficiency140 ±10 lm/W
Colour temperature (CCT)3000 K / 4000 K / 5000 K / 5700 K
Ingress protectionIP66
IK ratingIK10
Wind resistanceClass 17 (56.1–61.2 m/s)
Colour rendering indexRa > 70
Beam angle30° / 60° / 90°
Driver brandTOMCARLINE
Input voltageAC100–277 V / 277–480 V
Power factor> 0.9
Frequency47–63 Hz
Driver typeConstant current (CC)
Dimming1–10 V dimmable
Model No.HL101-50W / HL101-100W / HL101-150W / HL101-200W Power
50 W / 100 W / 150 W / 200 W Luminous flux (±10%)7,000 ±500 lm / 14,000 ±1,000 lm / 21,000 ±1,500 lm / 28,000 ±2,000 lm Product dimensions
330 × 265 × 190 mm (50 W, 100 W) / 385 × 317 × 190 mm (150 W, 200 W) Net weight12 kg / 12.3 kg / 15 kg / 15.5 kg Export carton size
43 × 41 × 27 cm (50 W, 100 W) / 48 × 45 × 27 cm (150 W, 200 W) Gross weight13.1 kg / 13.4 kg / 16.4 kg / 16.9 kg Packing information
1 pc per carton
AttributeDetail
Housing materialADC12 die-cast aluminium Housing build
Single cast body with integral front frame FinishPowder coating, heat-cured Fixture colour
Red Colour referenceRAL shade confirmed at order Optics
Tempered glass + lens Glass and lens serviceReplacement availability confirmed with supplier Mounting option
Bracket type / pole type Fixing interfaceBracket hole pattern and pole adaptor confirmed against your structure Cable entry
Gland size and entry position confirmed at order Ambient temperature−30 to +50 °C Life time
50,000 hours Net weight12–15.5 kg by model

Maintenance & Spare Parts

  • Cleaning on the mast is in-house work: a soft cloth, mild detergent and water on the tempered glass, no abrasive pads and no solvent, and no pressure washer aimed at the gland or bezel joint even though the fixture is IP66.
  • The inspection round covers five points: glass clarity, front bezel bolts, cable gland seating, the gasket line and the bracket pivots. A gland left loose after cable work is the usual way water finds its way into an explosion proof LED light.
  • Bolt and pivot checks count as much as the electrics: re-torque the U-bracket pivots and check the fixing behind the bracket, because a bracket that has crept shows up as a beam aimed off target on the next night round.
  • Set the interval by dust load rather than by calendar. A grain intake, crusher house or spray booth needs the glass cleaned far more often than a perimeter mast, and a film of dust on the lens is output already paid for on the energy bill.
  • Driver, LED board and internal wiring are workshop work. They sit inside the sealed enclosure, so plan a swap unit and a bench repair by a qualified technician rather than opening the housing on a ladder.
  • Hold one spare of the most-used wattage on site. A dark position in a classified area cannot wait for a repair turnaround, and a spare lets your own electricians restore light on the same shift.
  • Stock the parts that age: front glass and lens assembly, gasket and cable gland. Ask for the spare part numbers with the order so the kit matches the version actually supplied, since a gasket or gland for a different build will not seal. Note lens discolouration or uneven dimming at inspection; both point to a component nearing the end of its life, which is worth catching before a position goes dark.

Ordering & Delivery

The fixture is built to the combination you specify: power, colour temperature, beam angle, voltage version and mounting type. Two of those catch people out — the voltage version and the colour temperature. Tell us the distribution voltage at the point of connection and the CCT already standardised elsewhere in the plant, and every explosion proof LED light fixture on the order will match what is already installed. Each unit ships one piece per export carton, with gross weight running from 13.1 kg to 16.9 kg depending on the model, so anything above the 100 W sizes is a two-person lift. Net weights and carton dimensions are listed with the model data. If the project runs in phases, describe the sequence when you ask for the quotation — an explosion proof LED lighting order is easier to schedule before it is released than after. The fixture carries a 5-year warranty; confirm with your sales contact how claims are handled in your market, since the process differs by destination. Before release, check the confirmation sheet field by field — model, voltage, colour temperature, beam and mounting are the five that decide whether the delivery matches the site, and they carry more weight in industrial explosion proof lighting than in general lighting, because a wrong version cannot simply be swapped out on a hazardous site. Lead time, payment terms and shipping arrangements are quoted per order.

Testing & Compliance

Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.

FAQ

What supply voltage should I specify?

Two driver versions are available: AC100–277 V and AC277–480 V. The first covers conventional plant distribution and most retrofit work; the second is for sites running higher distribution voltages. Check the voltage at the point of connection rather than at the substation, because the two can differ by a tap setting — that is a common reason an explosion proof LED lighting order arrives with the wrong driver. If a site runs both, match each area rather than standardising on one version and adding transformers.

Which colour temperature suits a process plant?

Four options are available: 3000 K, 4000 K, 5000 K and 5700 K. 4000 K is the usual choice for process and storage areas because it keeps colours readable without the flat look of a very cool source. 5000 K and 5700 K get picked for inspection points, loading and dispatch areas, and anywhere detail has to be judged quickly. 3000 K suits walkways and perimeter lighting where a lower-glare source is easier on the eye at night. Ra > 70 on every version is enough for safety and task lighting, but it is not a colour-matching specification — if your site grades product colour under this explosion proof LED flood light, tell us and we will walk through the limits with you.

Is there a pole-mount version, and what pole does it fit?

Yes — the fixture is available with bracket type or pole type mounting. Pole diameters and spigot sizes vary from site to site, so send us the pole size you plan to use and we will confirm the adaptor before the order is placed. If the pole is already standing, measure the top section rather than the base; that is the dimension the adaptor has to match, and it is where most explosion proof LED light fixtures end up needing a second bracket.

How do you clean and inspect the fixture on site?

Wipe the tempered glass with a soft cloth and mild detergent, and avoid abrasive pads and solvent cleaners, which dull the glass over time. Check the front bezel bolts and the cable gland at each inspection — the IP66 rating depends on those seals staying seated, and a gland disturbed during cable work is the usual source of water ingress. The driver and LED array sit inside the sealed enclosure, so internal work is a workshop job rather than a site one. On a dusty site, cleaning the glass matters for output as much as appearance, because a film of dust on a LED explosion proof light is light you have already paid for.

How does it hold up to wind on an exposed mast?

Wind resistance is rated Class 17, which covers 56.1–61.2 m/s. What that rating rests on in practice is the bracket and the fixing behind it, so check the structure the bracket is going onto and re-check the pivot bolts after aiming. On an exposed mast the fixing and the bracket matter as much as the rating itself — that is true of any LED explosion-proof lighting installed on open ground, whatever the label says.

If I re-aim the fixture later, does the beam pattern change?

Re-aiming changes direction only; the beam pattern is set by the optic. If a position later needs a different spread, the optic is part of the sealed front assembly, so the practical answer is to order the beam version each position needs at layout stage rather than plan to change it on site. That is why we ask for a position list when an order covers a whole area — explosion proof LED lighting fixtures aimed at the wrong spread are usually a layout problem, not a product problem.