LED High Bay Light - Explosion Proof - HL180

Explosion proof LED high bay in 30 W and 50 W for Zones 1, 2, 21 and 22 and Class I Div 1/2 T5. 150 lm/W, IP66/IK10, 50 W emergency battery.
Download
View all downloads
  • Hazardous Area Explosion proof LED light HL180,New-Infinity,Hazardous Area Explosion proof LED light
  • Hazardous Area Explosion proof LED light HL180,New-Infinity,Hazardous Area Explosion proof LED light

Description

Product Overview

The HL180 is a compact explosion proof high bay LED light for classified areas where a standard high bay is not permitted — fuel terminals, paint and coating shops, chemical process buildings, grain handling, and the dusty or gassy corners of a general plant. The body is aluminium with a powder-coated red finish, closed over a tempered clear glass or PC milky optic.

Small enough to fit where larger fixtures will not, it suits mezzanines, pump skids, low-clearance bays, canopy undersides and walkway junctions. The range is deliberately short — 30 W, 50 W and a 50 W emergency build — which makes explosion proof LED high bay lighting simpler to specify: mounting height, and whether the circuit has to stay lit, are the only two questions.

We supply it as a high bay LED lighting supplier to process plants, terminals and industrial contractors, keeping one body and one bracket set across the three versions so a plant does not end up with three part numbers and three sets of spares.

Explosion Protection & Area Classification

The fixture is certified for Zones 1, 2, 21 and 22 and for Class I, Division 1 and Division 2 at temperature class T5. That covers gas or vapour atmospheres present in normal operation (Zone 1 / Division 1), atmospheres likely only under fault (Zone 2 / Division 2), and the dust zones 21 and 22 that apply to grain, flour, sugar, pigment and most powder handling. Gas and dust scope inside one explosion proof LED light fixture is what lets a site run a single standard instead of stocking two.

The area classification drawing decides, not the light. Match the zone and division on the drawing to the marking on the nameplate, check that the temperature class your process needs is no hotter than T5, and have your EHS team sign the marking off before the fixture goes up. Where a drawing calls for an explosion proof high bay LED light in Zone 2 only, this model also covers the Zone 1 positions alongside it, which usually removes a second line item from the order.

Certificates and test documentation travel with the order, so the marking on the housing, the paperwork in the project file and the drawing can be checked against each other at handover. That cross-check is where explosion proof LED lighting usually stalls in a site audit, and it closes faster when one family covers the whole classified area.

Harsh Environment Construction

  • Corrosion: the housing combines extruded 6063-T5 with ADC12 die-cast sections, finished in a red powder coat. There is no hinge, latch or plastic clip to crack, and the bolted joint compresses a gasket rather than relying on a snap fit — the parts that usually fail first on a chemical plant ceiling.
  • Vibration: no filament and no ballast to shake loose, so LED high bay lighting fixtures like this one hold up on pipe drops and machine decks near crushers, mixers and compressors.
  • Wind: rated LV.12 for canopy undersides, tank farm structures and open loading racks.
  • Washdown and impact: IP66 covers dust and high-pressure water jets, and IK10 covers knocks from forklifts, ladders and loading gear.
  • Ambient window: -20 °C to +50 °C operating and -30 °C to +60 °C storage, both at up to 85% relative humidity. Unheated warehouses and hot process buildings sit inside it.
  • Service life: rated for 50,000 hours — the figure to use when comparing it with re-lamping a conventional high bay.
  • Dust-heavy rooms: in grain, feed, flour and pigment halls, the kind of space served by LED warehouse lighting high bay fixtures, the sealed optical chamber keeps dust off the LEDs so output holds between cleaning cycles.

Efficiency & Running Costs

With the tempered clear glass optic the fixture reaches 150 lm/W: 4,500 ± 300 lm from 30 W and 7,500 ± 500 lm from 50 W. Against the conventional high-bay fixtures it is designed to replace, that is roughly 50% more light for the same electricity — which is why explosion proof LED high bay lighting is worth costing on running hours rather than on unit price. The PC milky cover build runs at 130 lm/W, giving 3,900 ± 300 lm at 30 W and 6,500 ± 500 lm at 50 W, and trades about 13% of the output for a 170° spread and a softer face. That trade pays over walkways, loading desks and inspection benches; it pays less over a rack aisle, where the 120° glass beam puts light where the work actually is. In industrial explosion proof lighting the second one matters as much as the first, because nobody opens the housing to clean it.

Mounting & Installation

  1. Choose the mounting format. Pendant pipe, shaped metal tube, direct ceiling and base mount all attach to the same body, so the fixing style already on your structure usually carries over without an adapter.
  2. Set the aim before you torque. The bracket is bolted to the body: loosen, aim, then draw it down. The 120° glass optic reaches further down a bay; the 170° PC cover fills a wider area from a lower fixing.
  3. Gland the entry properly. Every explosion proof LED light fixture in the range uses an M25 × 1.5 mm cable inlet, with sealing rings for Ø9–10.2 mm or Ø13–14.2 mm cable. Fit the ring that matches your sheath — a loose ring is the usual reason an IP66 housing weeps.
  4. Bond and close evenly. Earth the housing to the site earth and draw the body down evenly, so the gasket compresses flat instead of pinching on one side.
  5. Check headroom for the emergency version. The battery build is 22 mm deeper with either optic. Confirm the clearance above the fixing before the bracket goes up.
  6. Record the marking. Photograph the nameplate at handover — the zone, division and temperature class on the label are what an auditor checking explosion proof LED lighting will ask to see.

Applications

  • Oil and gas extraction and processing: wellhead areas, separator decks and process skids where gas is present in normal operation.
  • Oil and gas storage, transport and loading: tank farms, pump platforms, and rail and truck loading gantries.
  • Chemical plants: reactor halls, solvent handling and drum stores, where the powder-coated aluminium body has to shrug off the local atmosphere.
  • Mining and mineral processing: crusher houses, conveyor junctions and wash plants, where vibration and dust never stop.
  • Natural gas stations and power plants: regulating stations, compressor houses and turbine halls.
  • Grain storage and processing: silos, elevator heads, milling floors and bagging lines — dust Zone 21 and 22 work, and typical LED warehouse lighting high bay territory.
  • Food production: mixing, coating and packing halls that get washed down between shifts.
  • Spraying and coating: paint booths, mixing rooms and solvent stores — the classic industrial explosion proof lighting application, and the one where beam choice matters most.
  • Pharmaceutical and hazardous materials warehousing: dispensaries, flammable stores and drum halls.
  • Public facilities and vessels: plant rooms, tunnels, ferry decks and harbour structures.
  • Multi-building sites: one family across a plant keeps brackets, glands, colour temperature and spares identical — the practical reason buyers ask a high bay LED lighting supplier to standardise on a single range.
Collage of industrial facilities and work sites

Product Specifications

Model No.HL180-30W / HL180-50W / HL180-50W (Emergency)
Power30 W / 50 W / 50 W
Efficiency150 lm/W (tempered clear glass), 130 lm/W (PC milky cover)
Luminous flux (±10%)4,500 ± 300 lm / 7,500 ± 500 lm / 7,500 ± 500 lm (clear glass); 3,900 ± 300 lm / 6,500 ± 500 lm / 6,500 ± 500 lm (PC milky cover)
Beam angle120° (tempered clear glass), 170° (PC milky cover)
Colour temperature3000K / 4000K / 5000K / 5700K
Colour rendering indexRa > 70
Ingress protectionIP66
IK gradeIK10
Wind resistanceLV.12
DriverTOMCARLINE, constant current (CC)
Input voltageAC 120–277 V
Power factor> 0.95
Frequency47–63 Hz
PC milky coverØ182*200mm / Ø182*200mm / Ø182*222mm
Luminaire Net Weight2.5kg / 2.5kg / 3.7kg
Packing Information1PCS/CTN / 1PCS/CTN / 1PCS/CTN
Export Carton Size23.5*23.5*29.0cm / 23.5*23.5*29.0cm / 23.5*23.5*29.0cm
Gross Weight3.1kg / 3.1kg / 4.3kg
Dimensions of the cable inletM25x1.5mm
Wire diameter of sealing ringØ10.2mm-Ø9mm,Ø14.2mm-Ø13mm
Material (housing)6063-T5、ADC12
FinishPowder Coating
Mounting OptionPipe installation, Shaped metal tube installation, Ceiling installation, Base mount installation
Storage temperature range-30℃ - +60℃
Storage humidity range85% max.
Operating temperature range-20~+50℃
Operating humidity range85% max.
Life Time50000 hours
Warranty5 Years

Model & Optic Options

  • 30 W version: Φ182 × 141 mm with tempered clear glass, Φ182 × 200 mm with the PC milky cover; 2.5 kg net.
  • 50 W version: the same two dimensions; 2.5 kg net.
  • 50 W emergency version: Φ182 × 163 mm with clear glass, Φ182 × 222 mm with the PC cover; 3.7 kg net.
  • Clear glass when reach matters: a 120° beam at 150 lm/W — the choice for work areas, rack faces and anything several metres below the fixing.
  • PC milky cover when comfort matters: a 170° beam at 130 lm/W — the choice for low ceilings, walkways and positions where a bright point source would sit in someone's eyeline.
  • Colour temperature: 3000K, 4000K, 5000K or 5700K. Keep one CCT across an explosion proof high bay LED light installation so a room reads as a single system, and take a warmer option in areas that stay occupied at night.
  • One body across the range: every explosion proof LED light fixture in the family shares the same Φ182 mm housing, so brackets, glands and spares are common to all three versions.
  • 1. Normal running. The emergency version runs on mains like the standard 50 W unit and keeps its battery on charge. 2. Mains failure. Most LED high bay lighting fixtures go dark at this point; here a dedicated emergency driver takes over and runs the LED at more than 5 W — enough to keep an egress route lit, not enough to keep production running. 3. Runtime. Rated for more than 90 minutes at ambient temperatures between 10 °C and 60 °C, which covers a normal egress period with margin for a warm plant room. 4. Restore. When mains returns, the fixture goes back to full output and the battery recharges from the same supply. 5. Test regime. Prove the battery at handover, record the runtime in the emergency lighting log, and repeat it on the site's monthly schedule. 6. Placement. Put the emergency units on the egress route and at exit junctions rather than over the process; the battery is a life-safety allowance, not a production one.

Ordering & Delivery

Each unit ships one piece to a carton measuring 23.5 × 23.5 × 29.0 cm — 3.1 kg gross for the 30 W and standard 50 W, 4.3 kg for the emergency version. As a high bay LED lighting supplier we confirm the optic, colour temperature and emergency option against your purchase order before production, because those three choices define the part that gets built.

The luminaire carries a five-year warranty. Tell us at quotation stage which documents the project file needs — declaration of conformity, test reports, nameplate photographs for each explosion proof LED lighting item — and they can travel with the shipment instead of being chased afterwards.

Lead time, order quantities and freight terms are quoted per project. Send the room schedule with mounting types, mounting heights and the positions that need emergency units, and we will price the whole industrial explosion proof lighting package across the site. If you need to see the build before committing, ask your sales contact about sample availability and current lead times.

Testing & Compliance

Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.

FAQ

Which version do I need for a 5 m ceiling?

Mounting height and the task decide it. At around 5 m the 50 W version with the clear glass optic is the usual starting point; drop to the 30 W where the fixture sits closer to the work, covers a small footprint, or lights a walkway rather than a bench. If the positions sit above racking, put up one bay first and look at it — beam and rack geometry matter more than the wattage on paper.

Will it hold up in a grain or feed mill?

That is dust Zone 21 and 22 work, which the fixture is rated for. The optical chamber is sealed, so dust settles on the outside of the housing where a washdown or an air line reaches it rather than on the LEDs — the failure mode that makes LED warehouse lighting high bay units without a sealed optic fade between cleaning cycles.

How long does the emergency version keep the light on?

More than 90 minutes at ambient temperatures between 10 °C and 60 °C, on an emergency driver rated above 5 W. Treat that as an egress allowance rather than a production one: enough to walk a route out and see the panel, not enough to keep a line running. Test it at handover and record the runtime.

Can it be mounted outdoors on a loading gantry?

Within its ratings, yes: IP66, IK10, wind resistance LV.12 and an operating range of -20 °C to +50 °C at up to 85% relative humidity. Exposed canopies, tank farm structures and open loading racks are the sort of position this explosion proof LED high bay lighting is normally specified for. Keep the cable gland matched to the sheath and the enclosure stays sealed.

Can we reuse the existing pipe drops?

Pendant pipe, shaped metal tube, direct ceiling and base mount all fit the same body, so a run of LED high bay lighting fixtures already on pipe drops can usually be extended without new brackets. Check the thread and load rating of the drop on site before you order the bracket type.