IP66 40–80 W Explosion Proof LED Linear Light - OEM
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light

LED Linear Light - Explosion Proof - HL162

Sealed hazardous-area LED linear light in 40–80 W with standard or microwave motion-sensor bodies, IP66/IK10 and gas/dust zone markings.
Download
View all downloads
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light
  • Hazardous Area LED Linear Light HL162,New-Infinity,Hazardous Area LED Linear Light

Description

Product Overview

Hazardous areas in oil and gas plants, chemical works, mines, food plants and coating lines need light fittings that can sit inside the classified zone rather than outside it. This fixture is built for that job: a slim, sealed LED linear light available at 40 W, 60 W and 80 W, in a standard version or with a built-in microwave motion sensor. Its shape suits long runs — pipe racks, wall lines above tanks and walkways between process equipment — where a round high bay would throw light in the wrong direction. With explosion proof LED lighting, the nameplate marking decides whether a fitting can go into the area at all, so that is the first thing to check against your classification.

Most orders for this model come from plants fitting out a whole area rather than replacing a single lamp. We work as one of the industrial LED lighting suppliers on those projects, lining up colour temperature, beam angle and cable entry across every position so the finished installation reads as one system instead of a collection of fittings. If your electrical contractor is already on site, the mounting and gland details can be matched to what they are installing before the order is released.

The microwave version is the reason many buyers choose this body over a plain linear fixture: it follows occupancy instead of burning full output in an empty aisle. Standard and sensor versions can be mixed in one run, so a single order covers both the busy filling line and the tank farm walkway that is walked twice a shift.

Collage of industrial facility scenes at dusk and night, showing refineries, steelworks, storage tanks

Key Features

  • Certified for gas and dust zones. The nameplate carries Ex nR IIC T6 Gc and Ex tb IIIC T80°C Db, also written Ex db nR IIC T6 Gc; Ex tb IIIC T80°C Db, so this explosion proof LED light fixture can be installed in classified gas areas and in dust areas of the same plant. Match those markings to your area classification before ordering; if your zone calls for a different gas group or temperature class, tell us and we will point you to the body that fits.
  • IP66 and IK10 protection. Dust-tight and resistant to water jets, with an impact rating that takes knocks from tools, hoses and passing traffic. That combination is what lets the fixture stay in service in wash-down and outdoor positions instead of being boxed inside a second enclosure.
  • Extruded body with die-cast ends. The main body is a 6063-T5 aluminium extrusion and the end sections are ADC12 die-castings, finished in silver grey. Aluminium carries heat away from the LED board along the full length rather than through a small local heat sink, which is how the housing stays compact at 40–80 W.
  • Driver inside the length. Many linear LED light fixtures in this class need a separate driver box and a second cable run; here the driver sits inside the extrusion behind a screw-fastened cover, so what you install is one sealed piece from end to end.
  • Lens and PC optics. A clear lens over a polycarbonate optic shapes the beam and protects the emitters, and the flat outer face wipes clean easily. The optic is what produces the asymmetric distributions described further down, rather than a plain diffuser spreading light in every direction.
  • M25×1.5 cable entry. The threaded entry takes a sealing gland for cable from Φ8 mm to Φ14 mm, which covers the armoured and flexible cables normally used in classified areas. Cable outside that range needs a different gland, so check the cable schedule before the order goes in.
  • Three mounting methods from one body. Side wall brackets, direct ceiling fixing or a hoop mount, using the same bracket family across the industrial explosion proof lighting range, so a store room does not have to hold three different fixing kits.

Adjustable Coverage Area

  • 30×70° — long and narrow. An asymmetric spread that reaches forward and wide rather than straight down, which suits industrial LED lighting along wall runs, over rack faces and above pipe bridges where the target is a strip rather than a circle.
  • 40×130° — wide asymmetric. The widest of the asymmetric options. Useful when the fixture sits close to the surface it lights, such as a low wall mount over a working platform, and the beam has to open out quickly.
  • 60° — general purpose. A symmetrical cone that behaves predictably at most mounting heights and is the safest starting point when the layout is still being drawn for a linear LED light run.
  • 60×90° — corridors and runs. An elongated spread that follows a walkway, conveyor or line of linear LED light fixtures instead of spilling onto equipment either side of it.
  • 90° — broad coverage. The widest symmetric option, for low ceilings and open floor where the fitting sits close to the working plane and a narrow beam would leave dark bands between units.

Linear Model Comparison

AttributeHL161HL162
Power range30, 40, 60, 80 and 100 W40, 60 and 80 W
Luminous efficiency140±10 lm/W150±10 lm/W
Luminous flux4200±300 lm to 14000±1000 lm6000±400 lm to 12000±800 lm
Occupancy sensingnot offeredmicrowave sensor version, 100% on movement, 25% when the area is clear
DimmingDC 1–10 V interface for an external control systemsensor-driven dimming
Beam angles30°, 60°, 80° symmetric30×70°, 40×130°, 60°, 60×90°, 90°
Body dimensions630 × 136 × 87 mm / 1002 × 136 × 87 mm611 × 106 × 82 mm / 669 × 106 × 92 mm
Net weight6.5 kg to 10.5 kg2.9 kg to 3.0 kg
Cable entryNPT3/4-14 conduit openingM25×1.5 thread with gland for Φ8–Φ14 mm cable
Mountingside wall, ceiling, poleside wall, ceiling, hoop
Body colourredsilver grey
Where it fitslong runs that stay occupied all shift and take brightness commands from a control systemintermittently occupied walkways and wall or rack runs that need the beam shaped to the surface

Applications

The fixture is bought mostly by process plants where the lighting sits inside the classified area rather than outside it. Upstream oil and gas extraction and processing, tank farms, loading terminals, chemical and petrochemical plants, natural gas stations and power stations all use this body along pipe racks, above pump rows and on the walls of analyser houses. Industrial LED lighting for manufacturing plants of this kind usually goes in as part of a wider electrical package, so the mounting method and cable entry are agreed with the contractor before the order is released.

Further along the chain the same body turns up in mining and mineral processing, grain storage and processing, food production, spraying and coating operations, and pharmaceutical or hazardous-materials warehousing. In a spray area the sealed housing keeps solvent vapour away from the LED board and driver; in grain handling the smooth extrusion gives dust fewer ledges to settle on. Public facilities and vessels with classified spaces use it too, usually where a bulkhead fitting would be too large for the space. In every one of these positions, explosion proof LED lighting is installed for the same reason: the fitting has to be rated for the atmosphere it stands in, not just bright enough for the task.

Most of these areas are being re-lit rather than lit for the first time, with an older fluorescent or HID hazardous-area fitting coming out and this body going in. Because the supply cable usually already runs to the position, the questions that decide the schedule are the gland size, the bracket centres and whether the existing support will carry the weight — at around three kilos the fixture is light enough for most existing wall brackets and trunking. Where an area is being reclassified or extended, the layout is normally drawn around the beam angles rather than around the footprint of the housing.

Product Specifications

ModelHL162-40W / HL162-60W / HL162-80W
Dimensions611 × 106 × 82 mm (standard) / 669 × 106 × 92 mm (microwave)
Colour temperature3000K / 4000K / 5000K / 5700K
Colour rendering indexRa > 70
Protection gradeIP66
Impact ratingIK10
Wind resistanceClass 12
Input voltageAC120–277 V
Frequency50/60 Hz
Net weight2.9 kg (standard) / 3.0 kg (microwave)
Explosion-proof markingEx nR IIC T6 Gc; Ex tb IIIC T80°C Db (Ex db nR IIC T6 Gc; Ex tb IIIC T80°C Db)
PropertyValue
Luminous efficiency150±10 lm/W 40 W model
6000±400 lm 60 W model9000±600 lm 80 W model
12000±800 lm Energy use against standard productsaround 50% lower for the same light Power factor
> 0.9 Power supply typeconstant current Sensor dim level (microwave version)
100% on occupancy, 25% when the area is clear Sensor coverageadjustable angle settings for different detection areas Rated life
50,000 hours

Motion Sensing and Automatic Dimming

  1. Movement detected. The microwave sensor registers a person or a vehicle entering its detection area and brings the fixture to full output — 100% of whatever wattage you ordered.
  2. Area occupied. Output stays at full brightness while there is movement, so the work zone keeps the light level the layout was designed around.
  3. Area empty. Once no movement is detected, the fixture dims to 25% rather than switching off, which keeps walkways, gauges and escape routes visible without burning full power.
  4. Someone returns. The next movement brings it straight back to full output, with no warm-up wait and no restart delay from this driver.
  5. Which positions suit it. Intermittently occupied places gain most: tank farm walkways, pump rows visited on rounds, storage bays, remote galleries and service corridors, where explosion proof LED lighting would otherwise run at full output in an empty space for most of the shift. A line that keeps people walking past all day gains little, and the standard body is the sensible choice there.
  6. What commissioning needs to know. The sensor is a dimming control, not a switch on the circuit, so the fixture needs permanent power. If a timer or contactor cuts the lighting circuit overnight, the sensor has nothing to work with and the area behaves as a switch-off instead of a dim-down.

Maintenance & Care

  • Upkeep on this body is cleaning and inspection rather than component replacement.
  • The cleaning interval follows the dust load, not the calendar quarter. Grain handling, coating and cement dust coat a lens quickly and justify a monthly wipe; a clean process hall or a tank farm walkway usually holds its output on a quarterly clean. Fix the interval after the first inspection, when the actual build-up on the lens is visible.
  • Batch the fixtures into one at-height visit. A platform or tower has to be brought in whatever the number of fittings, so clean a whole run in one session and tie it to other work at that level; sending someone up for a single body is how maintenance hours disappear on a plant with a hundred positions.
  • Look at the fixing, not only at the light. Side wall brackets, ceiling fixings and hoop mounts carry a body of about 3 kg, and vibration on a pipe rack works screws loose over the years. Checking bracket and cover fixings at each clean catches the failures a light-level check never shows.
  • The sensor face needs the same attention as the lens on the microwave version. A label, a film of overspray or a heavy dust layer over that face shortens detection range and can leave the fixture sitting at 25% while the aisle is in use — wipe it in the same pass and never tape over it.
  • Wash within the rating. IP66 covers a low-pressure rinse of the outside of the body, but a high-pressure jet held against the gland or the cover joint will find any weakness, so rinse along the extrusion rather than into the cable entry and never open the driver compartment for cleaning.
  • Units held back for a later phase should stay in their sealed carton in a dry store, with nothing stacked against the lens face; a lens scuffed in the store room is as much of a problem as one damaged on site.

Ordering and Delivery

  1. Share the area classification. Plants that buy from industrial LED lighting suppliers usually start with the classification drawing rather than a part number, and that is the right order of work: send the zone, gas group and temperature class your safety officer works to, plus a sketch or photo of each position. We check the nameplate marking on this explosion proof LED light fixture against it and tell you straight away if another body would serve the area better.
  2. Decide standard or sensor, run by run. A filling line that is busy all shift and a tank farm walkway visited twice a day do not need the same behaviour. For LED lighting for manufacturing plants, the standard body is the sensible default in busy areas; the microwave version is the one that returns energy where the area empties.
  3. Fix the beam angle position by position. Wall runs, rack aisles and open floor each want a different spread, and agreeing it at order stage is far cheaper than correcting it on site. Tell us the mounting height and the width you need lit and we will propose a combination from the industrial explosion proof lighting range.
  4. Confirm the electrical details. Colour temperature, supply voltage and how many units sit on each circuit are settled before production starts, so drivers and glands match the site rather than the store room.
  5. Agree packing and schedule. Each fixture travels as one piece per carton, measuring 74.3 × 17.0 × 14.8 cm, at 3.7 kg gross for the standard body and 3.8 kg for the microwave version. The five-year warranty runs from delivery. Confirm the current lead time, payment terms and shipping arrangement with your sales contact, and ask about sample availability if your team wants to inspect one before the full order.
  6. Keep later phases consistent. If the plant is being re-lit in stages, either place the whole run in one configuration or record the exact specification of the first phase. Mixing bodies with different colour temperatures or beam angles between phases is the most common way a finished installation ends up looking patchwork.

Testing & Compliance

Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.

FAQ

Which colour temperature should I choose?

Neutral white around 4000K is the usual choice for process areas: it keeps colours close to daylight without the blue cast of a very cool white, which makes gauge faces and product colours easier to read. Cooler options are common where inspection or fine assembly work needs maximum contrast, and the warmest option suits walkways and rest areas where glare is more of a nuisance than fine detail. The temperature is fixed per order, so decide it with as much care as the beam angle — and if a hall is being fitted in phases, hold the same value across the whole run of LED lighting for manufacturing plants so the far end does not read as a different space.

Can the same body go on 120 V and 277 V circuits?

Yes. The driver is rated across the 120–277 V band at 50/60 Hz, so a 208 V or 240 V site and a 277 V lighting circuit can use the same body without a different order code. Confirm the actual supply voltage and whether the circuit is single- or three-phase when you order, because the gland and internal wiring are chosen at that point. Sites that standardise their industrial LED lighting on one voltage keep the wide-range body as the stock item for legacy areas, and contractors like it because linear LED light fixtures with this input range can be moved between buildings during a retrofit without a re-order.

How does this model compare with the HL161 linear light?

Both are sealed linear bodies for classified areas, but they are specified for different jobs. The HL161 covers 30–100 W with a 1–10 V dimming interface and no occupancy sensor; this model runs 40–80 W, adds the microwave sensor version, and gives you asymmetric beam options for wall and rack runs. If an area is occupied all shift and you want external dimming control, the HL161 is the better fit; if the area empties regularly, the sensor here does the work. Send the zone classification and a sketch of the area and we will tell you which of the two we would put in each position — that comparison is part of the industrial explosion proof lighting work we do before a quotation.

Do the standard and microwave versions install the same way?

Yes. Both use the same sealing gland size, the same threaded entry and the same side wall, ceiling or hoop brackets, so the two versions can sit next to each other on one circuit and share a fixing detail. The difference is body length: the sensor version is slightly longer, so set bracket centres from the drawing for the version you are actually ordering rather than from the other one. Weight is close enough that the same fixing method carries either, so a sensor body drops into a layout drawn for the standard led linear light without redrawing supports.

What maintenance does it need in a dusty plant?

Very little beyond keeping the optic clean. The lens is flat and sealed, so dust settles on the outside where a wipe removes it rather than inside the optical chamber; add it to the normal lighting inspection round and check the gland is tight whenever cable work happens nearby. Where the atmosphere coats surfaces quickly, a planned clean every few months keeps output where it was on day one. Two things an inspector looks at first on any explosion proof LED light fixture are a legible nameplate and an undamaged lens, so make both part of the check. If your team buys through industrial LED lighting suppliers regularly, ask your contact to include spare glands with the shipment and to keep the marking details on file for the next phase.