Explosion Proof LED Light - Industrial Lighting Supplier
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights

LED Explosion Proof Light - New-Infinity

Die-cast aluminium explosion proof LED light in 50 W and 100 W outputs, 180 lm/W, IP66 sealing and EN55015 compliance, for oil, gas and chemical sites.
Download
View all downloads
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights
  • LED Explosion Proof Lights,MY SHOP,LED Explosion Proof Lights

Description

Product Overview

This explosion proof LED light fixture is a high-output luminaire for working areas where flammable gas, vapour or combustible dust is part of the everyday environment. A circular LED array sits behind a clear domed glass lens, the lens is clamped down by a bolted rim on a die-cast aluminium body, and the rear of the housing is finned so heat leaves the fixture instead of building up around the LEDs. Two outputs cover most bays: 50 W at 9,000 lm and 100 W at 18,000 lm, both at 180 lm/W.

It is specified by plant engineers, EHS managers and maintenance teams who need a fixture a safety inspector will accept and an electrician can service without dismantling the ceiling. Typical duties are oil and gas processing areas, chemical production and storage floors, steel plants, paint and coating booths, and hazardous-materials warehouses.

Where a metal-halide or fluorescent hazardous-area fitting already hangs, the mounting pattern and the wide input voltage mean the replacement usually goes onto the same ceiling or wall position from the same supply. The light itself is cool white at 6000K with a 120° distribution, so it fills a bay rather than punching a narrow spot into the middle of it — useful for pipework, walkways, control panels and the faces of the people working underneath.

The VIS-.FB is one body in a wider hazardous-area family. Where led lighting for manufacturing plants has to work under a very tall roof, this round body is usually the answer; long runs along a production line or a racking aisle are better served by a linear body, and perimeter roads, tank-farm roads and loading yards by a street body.

- A wide, even field. The 120° optic fills a bay instead of punching a spot into the middle of it, so pipework, valves and walkway edges stay visible without adding fittings. - Output that reduces the fixture count. Nine thousand lumens from the 50 W body and eighteen thousand from the 100 W body mean fewer mounting points, less cable and fewer sealed entries to maintain in a tall roof. - Voltage flexibility across a site. One body covers 110–265 V supplies, so a 120 V building and a 230 V building in the same plant can share the same spare. - Quiet on the supply. High power factor, an efficient driver and EN55015 compliance matter where variable-speed drives, instrumentation and lighting share a distribution board. - Cool running. The finned rear housing moves heat out of the LED chamber, which is what keeps output and colour stable through a shift rather than drifting as the fixture soaks. - Service in place. The bolted rim and glass dome come off without dropping the bracket, so an electrician can clean the lens or replace the driver from a platform instead of rebuilding the mounting. - Suited to industrial led high bay light duty. Round, high-output bodies like this one are the usual choice for open bays with high ceilings, where light has to travel down past crane rails, ductwork and racking. - One platform across explosion proof led high bay lighting. The same LED source and driver approach continues in the linear and street bodies, which keeps a plant to one spares policy and one documentation set.

Housing and Build

The body is a single die-cast aluminium casting, painted yellow grey as standard and available in black. Casting rather than pressing is what gives the housing its thickness at the flange, and that thickness is what lets the glass dome be clamped down hard enough to stay sealed through years of heating and cooling. The dome is clear glass over a circular LED array, held by a bolted rim rather than a twist ring, so nothing works loose under vibration.

Heat leaves through the finned rear of the casting. That geometry is why a compact body can run a high output without cooking its own LEDs: the fins add surface area and the aluminium carries heat away from the board. In practice you get stable output and stable colour across a long shift instead of a slow drift as the fixture warms up.

Led explosion proof lighting lives or dies on the details at the cable entry and the joint faces. The supply enters through a gland in the housing, the joint faces are machined, and the assembly is designed to be opened for service without losing its seal afterwards. Painted aluminium also handles the acid mist, salt air and washdown chemicals that eat through cheaper housings.

The mounting bracket is a U-shaped yoke with a pivot bolt, so the body can be aimed and locked. That matters in a tall bay, where an industrial led high bay light rarely hangs over a flat, empty floor — tilting it a few degrees often puts the light on the walkway instead of the crane rail.

Certification and Compliance

This fixture holds an explosion-proof certification and an IP66 rating. Those two items are the ones that matter in led explosion proof lighting, because between them they answer the two questions an inspector actually asks: can the fixture ignite the atmosphere, and can it keep the atmosphere out of its own interior.

What gets checked on site is the certificate and the nameplate, so make sure the marking on the label covers the area you are installing into, and keep the certificate with the fixture documentation rather than in a project folder nobody can find. Industrial explosion proof lighting is judged on that paperwork as much as on the hardware — a perfectly good fixture with the wrong marking is still a finding.

The glass dome, the machined joint faces and the gland entry are all part of how an explosion proof led light fixture keeps its certification in service. That is why the assembly is designed to be re-opened and re-sealed, and why the gland must be matched to the cable rather than packed with tape. If your authority or your insurer asks for a specific document set, tell us before shipment and we will confirm what can be supplied with the goods.

Hazardous Area Classification

  • Zone comes first. Gas atmospheres are divided into Zone 0, 1 and 2 by how often the hazard is present, and dust into Zone 20, 21 and 22. The zone on your area drawing decides the marking the fixture has to carry, so it is worth settling before anyone argues about wattage.
  • Gas group and temperature class follow. Two more columns sit on the same nameplate: the gas group and the temperature class, which sets the hottest surface the fixture may reach. A fixture that covers your group but not your class is not a match, however good the light output is.
  • Ask for the certificate, not just the word. Every supplier describes a body as explosion-proof.
  • Dust is a separate conversation. Grain, sugar, starch, pharmaceutical powder and additive handling create combustible dust layers, and the fixture has to be sealed and rated for the dust zone, not only for gas.
  • Corrosive and wet conditions usually run alongside. Chemical plants, coastal terminals and washdown areas punish housings, which is why the die-cast aluminium body, the painted finish and the bolted glass dome carry as much weight here as the electronics do.
  • Body shape follows the space. Open bays with tall ceilings suit this round high-output body; long runs along a line or an aisle suit a linear body; perimeter roads, tank-farm roads and yards suit a street body. Getting that wrong is the most common and most expensive mistake on a hazardous-area retrofit.
  • Mounting height sets the distribution. A wide distribution covers a broad area from a moderate height; where the roof is very high, explosion proof led high bay lighting needs a tighter body in the family to put more light on the floor from the same wattage.

Installation and Mounting

  1. Settle the marking against the area drawing before anything leaves the store. Confirm zone, gas group and temperature class with your EHS lead and check them against the certificate that travels with the goods.
  2. Isolate and lock off the circuit. Check that the supply voltage falls inside the 110–265 V window, which is what lets led explosion proof lighting use the existing circuit without a transformer tap change or step-down.
  3. Fix the U-shaped bracket to the ceiling or wall, set the body angle with the pivot bolt, and tighten it. The bracket carries the weight of the explosion proof led light fixture, so the body can be aimed afterwards without disturbing the fixings.
  4. Bring the supply in through the gland, sized to the cable, and seal it properly. A gland that is left loose is the most common reason a sealed fixture fills with moisture.
  5. Energise and check output and coverage against the layout — look at the floor, not just at the fixture. Adjust the tilt before the platform comes down.
  6. Record the fixture in the site's lighting register and hand the certificate and datasheet to whoever keeps the hazardous-area file. The next inspection will ask for them.

Application Scope

  • Hazardous zones are rarely confined to one building. A single site can hold a classified process hall, a drum store, a loading bay and a tank farm, each with its own zone and its own mounting conditions. This fixture suits illumination in chemical plants, oil drilling rigs and mining operations where a certified body has to keep working shift after shift without being nursed.
  • Integration matters as much as output. Industrial explosion proof lighting usually replaces an existing fitting on an existing circuit, so the wide input voltage, the ceiling or wall bracket and the gland entry let the swap happen inside a normal shutdown window rather than turning into a re-cabling project. Where a plant is being extended, the same body can be specified for the new area and the existing one.
  • Where led lighting for manufacturing plants has to cover long process halls, the units are spaced along the ceiling rather than concentrated over one machine, which spreads the load across circuits and keeps a single failure from blacking out a whole bay. Share the hall drawing and mounting height and we will work out the spacing with you.
  • It is the wrong answer for offices, control rooms, laboratories and clean corridors. Those areas are not classified, and a panel or linear fixture gives better visual comfort for the money. It is also not a roadway fitting — for perimeter roads and external haul routes, the street body in the family does that job properly.
  • Drill floors and wellheads. The fixture is the working light around the rotary area, where vapour is present and the mounting has to survive constant vibration. - Processing and separation trains. Mounted above pumps, manifolds and valve rows, the wide distribution puts light on the equipment rather than between it. - Tank farms and bund areas. A sealed aluminium body and a bolted glass dome cope with the coastal air and the temperature swings that come with an open bund. - Loading racks and jetty berths. Transfer operations create a vapour envelope exactly where the operator needs to see the coupling, the hose and the grounding point. - Compressor, metering and remote stations. These are often unattended for weeks, so the long service interval and stable output matter more than the purchase price. - Turnarounds and maintenance campaigns. Temporary lighting around an open flange or a scaffold is exactly where a portable, aimable body earns its place; the pivot bolt lets it be pointed at the work face. - A dependable industrial led high bay light for high structures. Where the structure is tall and the fittings are hard to reach, fewer, higher-output units mean fewer access requests over the life of the installation.
  • Chemical production is where the case for a sealed metal fixture is easiest to make. Led lighting for manufacturing plants in this sector has to survive solvent vapour, acid mist, process dust and the washdown that follows a spill, and it has to do it while sitting in an area that is classified for a reason. The die-cast aluminium housing and the painted finish resist the corrosion that turns thin steel housings into a maintenance item within a couple of years. The glass dome is bolted rather than clipped, which matters when the atmosphere attacks plastic fittings and when a seal has to be re-made after someone opens the fixture on site. role decides how useful the installation is. Reactor bays, dosing stations, drum and IBC storage, pump rows and the walkways between them all want light on the equipment and on the floor, and a 120° distribution at a sensible mounting height does that without a forest of brackets. Visibility around critical equipment also shows up in the audit trail. Labels, gauge faces, valve handles and PPE all read more clearly under steady cool-white light, and night inspection rounds are quicker when the same bay looks the same at three in the morning as it did at the start of the shift.
  • Building facades and plant perimeter. A sealed explosion proof led light fixture washes a wall or a walkway edge where a standard floodlight would not be accepted. - Stadiums and sports fields. High mounting, wide coverage and a robust body suit the lighting towers that sit inside or beside industrial sites. - Construction sites. Where plant is being built or expanded inside a classified boundary, the same fixture serves as temporary and then permanent lighting. - Docks and ports. Salt air, wind-driven rain and continuous operation are the normal conditions rather than the exception. - Mining areas. Dust, vibration and wide temperature swings are the design case, not an occasional event. - Industrial yards. Loading and marshalling areas where the light has to reach the ground and the vehicle cabs without glare into the mirrors. - Security lighting. A cool-white explosion proof led high bay lighting layout that stays on all night also keeps camera images usable and deters intrusion at the fence line.
Collage of industrial facilities with overhead lighting in use

Technical Specifications

ParameterSpecification
ModelVIS-.FB
Power50W / 100W
Luminous Flux9,000 lm / 18,000 lm
Luminous Efficacy180 lm/W
Colour Temperature6000K cool white
Colour Rendering Index (CRI)Ra > 70
Beam Angle120°
Input VoltageAC 110-265V, 50/60Hz
Power Factor>0.95
Driver Efficiency>96%
Total Harmonic DistortionTHD
EMI ComplianceEN55015
LED SourceVIS Brand LEDs
ParameterSpecification
Housing materialDie-cast Aluminum
Yellow grey / black (optional) MountingCeiling / wall mounted Input voltage
AC 110-265V, 50/60Hz Power factor>0.95 Driver efficiency
>96% EMI complianceEN55015 Light engine
VIS brand LEDs Colour renderingCRI Ra > 70 Operating temperature
-20 °C to +60 °C IP ratingIP66 Lifetime
> 50,000 hours Warranty3 years

Customization Options

Where the work is colour-critical — cable identification, sample matching, inspection benches — a higher CRI version at Ra > 80 is available, and the colour temperature can be set to 3000K, 4000K or 5000K instead of 6000K. Mixing colour temperatures across one plant is a decision worth making once, because stores, walkways and process areas often want different things. Housing colour is yellow grey by default and black as an option. That is mostly a site convention: some operators colour-code by zone, others want the fixtures to disappear into a dark roof space. Control options include a photocell for dusk-to-dawn switching and a motion sensor for areas that are only intermittently occupied, and surge protection can be added where the supply is exposed to switching transients or lightning. Industrial led lighting solutions are rarely one-size, so treat the specification as a starting point rather than a fixed catalogue entry. If your site needs a different colour temperature, a different marking or a different control arrangement, send the requirement with the area drawing and we will confirm what can be built and what cannot.

Ordering and Delivery

  • Send the area schedule, not just a quantity. Wattage, colour temperature, CRI version, housing colour, sensor and surge options can differ by zone inside the same plant, and the order is built from that schedule.
  • Confirm the delivery date against your shutdown window. Tell us when the electrical contractor is on site and we will confirm what the batch can do — we do not publish a lead time we have not checked with the supply chain for your configuration.
  • Packing and carton quantities are confirmed on the order confirmation so the goods arrive in a form your stores can handle and count.
  • Documentation travels with the order. Certificates, declarations and datasheets can be prepared in the language your auditor works in if you say which one before shipment.
  • Staged delivery for phased retrofits. Where industrial explosion proof lighting is being rolled out building by building, deliveries are scheduled to the contractor's programme so nothing sits in an open yard waiting to be installed.
  • Repeat orders and spares. We buy through certified partner manufacturers, so a second order for the same plant comes from the same supply chain rather than from whatever batch happens to be available.
  • Keep a spare body per zone type on site. A failed fixture in a classified area cannot be replaced temporarily with a non-certified unit, so a spare shortens the window in which an area is dark.
  • Ask for the dimensional drawing and net weight if your contractor needs them for the mounting layout or lifting plan before the order is placed.
  • Build the business case with us if you need to. Industrial led lighting solutions are usually approved on a payback figure, so we can put fixture count, wattage and running hours into a before-and-after comparison for your own plant.

Testing & Compliance

Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.

FAQ

What materials are used in the construction of the LED Explosion Proof Light?

The housing is die-cast aluminium, finished in yellow grey as standard with black available as an option. The lens is clear glass clamped down by a bolted rim over the LED array, and the heat path is metal rather than plastic so the body keeps its shape through temperature swings. Aluminium is chosen for the combination that matters here: it conducts heat away from the LEDs, it does not crack under vibration, and it resists the corrosive atmosphere found around chemical plants and coastal terminals. The supply enters through a gland in the housing, and the mounting yoke is metal with a pivot bolt so the body can be aimed and locked.

Can I customize the LED Explosion Proof Light for different industrial applications?

Yes. The 6000K standard build can be supplied at 3000K, 4000K or 5000K, a higher CRI version at Ra > 80 is available for colour-critical work, and the housing can be ordered in black instead of yellow grey. Photocell and motion-sensor control can be added, along with surge protection where the supply is exposed. Because led lighting for manufacturing plants usually has to serve several zones at once, the practical approach is to send one schedule listing each area with its own requirement and let us confirm the build per area.

Is installation of the LED Explosion Proof Light complicated for industrial facilities?

No. An explosion proof led light fixture of this type mounts on a U-shaped bracket fixed to a ceiling or wall, the body angle is set with a pivot bolt, and the supply terminates through a gland. The wide input voltage means there is no transformer tap change when the site runs on 120 V or 230 V. What does need care is the detail: the gland must be sized to the cable and sealed, and the marking must be checked against the area before the fixture is energised. A competent site electrician can do the work; we supply the mounting and commissioning information with the goods.

Should I choose the 50 W or the 100 W version?

Both run at the same efficacy and the same 120° distribution, so the choice is really about height and area. The 50 W body delivers 9,000 lm and suits lower roofs, smaller bays, walkway lighting and areas where the fixtures can be spaced more closely. The 100 W body at 18,000 lm is the one for tall open bays, large process halls and locations where access to change a fitting is expensive. On a very tall roof, fewer 100 W units generally beat more 50 W units on installed cost, because the mounting and cable work per point usually costs more than the difference in fixture price.

How much area does one fixture actually light?

That depends on mounting height, the reflectance of the surfaces and the task, so we calculate it from your drawing rather than quoting a blanket figure. As a working shape: the 120° optic spreads quickly, which is what makes it good general bay lighting, and it also means the fixture should not be mounted so high that the cone is diluted before it reaches the floor. Send the hall dimensions, the mounting height and what has to be visible underneath — valve rows, racking faces, walkways — and we will come back with a spacing and a fixture count you can check against a light meter after installation.

What maintenance does the fixture need once it is running?

Very little beyond inspection. Wipe the glass dome when dust or overspray builds up, because a dirty lens costs light long before the LEDs lose output. Check the gland and the joint faces at each scheduled electrical inspection, especially after any work that involved opening the fixture, and re-seal properly if it has been opened. The rated life is over 50,000 hours, so on a normal shift pattern the driver, not the LED array, is the part that eventually needs attention — and it is reachable from the front of the fixture without removing the bracket. Keeping one spare body per zone type means a failure never leaves an area dark while a replacement is ordered.

What should I check about my site before the order is placed?

Four things decide the build. The zone classification and the gas group or dust group with its temperature class, taken from your area drawing rather than from memory. The mounting height and the surface you are fixing to, because that sets the wattage and the bracket arrangement. The supply voltage and whether the circuit is generator-backed or exposed to surges. And the ambient conditions — coastal air, washdown chemicals, high dust or a cold store all change what we recommend. Send those four and we will confirm the configuration; if you are also weighing up industrial led lighting solutions across several buildings, include the building list in the same message so the whole project is quoted together.