Product Overview
Halfway between a yard flood and a process-area fixture, this explosion proof LED flood light is built around a sealed aluminium alloy body, a PC and tempered glass front, and a bracket that lets you re-aim it long after it is bolted to the steel. It runs from 25W to 300W across eight models, so one family covers the walkway at the edge of a site and the mast position over a loading yard. The output range is the useful part. Both builds share the housing, the driver approach and the mounting bracket, which means one spare unit and one set of aiming notes for the maintenance team instead of three. Fixtures are powder-coated black and mount on a bracket, so they sit comfortably on structural steel, masonry walls and pole adaptors alike. Unlike LED explosion proof lighting that stops at 150W, this range carries on to 300W. That is usually where a single family becomes easier to standardise across a whole site than three separate product lines with three separate spares lists. - Eight wattages, one housing family. 25W, 45W, 75W, 100W, 150W, 200W, 240W and 300W share the same body and bracket, so spares, aiming notes and training stay common across a site. - Aluminium alloy body, PC and tempered glass front. The housing is the heat path as well as the structure, and the glass face keeps its clarity when abrasive dust is blowing across the site. - Bracket mounting with a pivot bolt. Aim from underneath, lock off, and correct the throw later without disturbing the supply. - Built for retrofit work. The bracket fixes to columns, walls and steelwork and the supply enters through a gland on the underside, so replacing an older flood inside an existing industrial LED lighting solutions scheme rarely means new conduit.
Thermal, Driver & Dimming Performance
An LED flood lives or dies on how it moves heat. On this series the aluminium alloy housing does two jobs at once: it is the structure and it is the heat path, drawing warmth off the LED board and spreading it across the body so the diodes stay inside their comfort zone on a hot afternoon in a roof void. The front glass is seated in the frame rather than floating loose in a channel, which keeps the optical chamber clean and stops dust settling onto the diodes.
The electrical side is deliberately conservative. A constant-current driver holds the current steady as the supply moves, the input range covers the nominal voltages used across Europe, the Middle East and much of Asia without a step-down transformer, and either mains frequency is accepted without a setting to change. On a site with heavy motors and frequent switching, that combination is worth more than a slightly higher headline figure from a cheaper driver.
Dimming earns its keep in two places: outdoor yards where the required light level drops after the last shift, and process areas where you want to hold a floor of illumination for camera coverage at night without paying full wattage for it. Run the control cable while the steel is still accessible; adding it later to an industrial warehouse lighting installation, once a finished ceiling or a pipe rack is in the way, is the expensive version of the same job.
As an industrial LED lighting manufacturer working through partner factories, we match the driver to the thermal design rather than treating them as two separate purchases. That is how a single industrial LED lighting solutions range can carry the same body, the same bracket and the same maintenance procedure in either efficiency build, without the site noticing a difference.
Housing, Finish & Operating Limits
- Aluminium alloy housing. The body carries the LED board, spreads the heat and takes the mounting load, so bracket bolts have metal to bite into rather than a plastic shell that creeps over time.
- PC plus tempered glass front. The glass face resists abrasion from blowing grit and keeps its transmission, while the polycarbonate layer behind it absorbs the shock of a glancing impact.
- Powder-coated finish. Powder coating matters more than most buyers expect in industrial explosion proof lighting: on a coastal or chemical site it is the barrier between the aluminium and the salt or acid attack that pits a housing and seizes bracket bolts.
- Black fixture colour, bracket mounting. The dark finish keeps the fixture visually quiet on a plant structure, which matters on facades and near occupied buildings.
- Storage window of -30 °C to +80 °C at 85% maximum relative humidity. Wide enough for an uninsulated site container or a warehouse that is not climate controlled, so spares can be held on site without a heated store.
- Operating window of -30 °C to +45 °C at 85% maximum relative humidity. This covers a cold-store yard and a hot process hall, but if your summer ambient regularly climbs above that ceiling, tell us before you specify — the fixture will run, but driver life is tied to how hot it gets, and a different build may serve you better.
- What the two windows mean in practice. Cold does not damage the fixture, but it does stiffen cable glands at installation time, so avoid fitting below freezing where possible; sustained humidity near the ceiling of the range is the signal to check the gland and seal at commissioning.
- Process areas that need industrial explosion proof lighting are not ordinary lighting projects. The fixture goes where flammable gas, vapour or combustible dust can be present, and where the safety case, the insurer and the customer audit all expect the luminaire to suit that exact location. That changes what matters: a seal that stays a seal after years of thermal cycling, a glass face that does not craze, and a driver that does not cook itself in a still, hot corner of a plant room. The 25W to 300W spread is what makes one family practical here. A tank farm perimeter, a pump house interior, a loading gantry and a dusty bagging hall rarely want the same wattage, but they do want the same mounting detail, the same spare and the same documentation set. Running one family across all four keeps the stores shelf small and the inspection routine familiar. Facility managers also get the paperwork benefit. Instead of assembling a folder of paperwork from five product lines, the site ends up with one family, one specification sheet and one installation pattern that electricians learn once. What separates LED explosion proof lighting in this class is not the first year, it is the fourth, after the seals have been through a few hundred heating and cooling cycles in a corrosive atmosphere. The aluminium housing, the glass front and the constant-current driver are specified for that, and the IP66 and IK08 ratings are the parts of that promise a buyer can measure.
Industrial & Hazardous Site Applications
The fixture works in the places where contamination, dust and an explosive atmosphere all show up in the same shift: petrochemical plants, chemical works, manufacturing facilities and the classified zones inside warehouses that need industrial explosion proof lighting. In each case the job is the same — raise ambient visibility so people can see what they are doing, keep the installation inside the site's safety case, and stop paying for light nobody is using.
Integration matters as much as output. Because the fixture is bracket-mounted and aimed from underneath, it can be added to existing steelwork without modifying the structure, and the supply enters from below where cable routes already run. On sites that monitor lighting circuits through a building management system, the dimming driver lets a fixture sit on the same control layer as the rest of the installation rather than being a manual island.
Maintenance teams running LED lighting for manufacturing plants get a fixture they can inspect from a lift without opening anything. There are no lamps to change, no ballast door to unclip, and the aiming record from commissioning stays valid because the pivot bolt locks the angle in place.
For a site that also runs industrial warehouse lighting in its non-classified bays, the same bracket, the same spare and the same aiming method carry straight across, which keeps the electrical team working to one procedure instead of three.
In a petrochemical plant the lighting has to survive two things at once: an atmosphere that can carry flammable vapour, and an environment that eats metal. Corrosive attack is the slow killer in LED explosion proof lighting — salt, hydrogen sulphide and process vapour go after fixings, painted steel and cable entries long before the LEDs themselves give up. That is why the powder-coated aluminium housing and the underside cable gland matter as much as the lumen figure. Continuous exposure also changes the maintenance model. Fixtures in a process unit are usually reached on a planned outage, not on demand, so a unit that fails between outages stays dark until the next window. Sealed construction and a constant-current driver reduce the chance of that call, and the bracket allows a like-for-like swap without re-drilling or re-aiming from scratch. Where the plant runs lighting through a monitoring or control layer, the dimming option lets the circuit follow a night-time profile or hold a minimum level for camera coverage, rather than burning full wattage on an empty unit. That is a small share of the site load, but it is the share that is easiest to control without touching production. Emergency readiness is the other half of the brief. Lighting that is reliably on is part of how a control room sees a release, a leak or a person down, and part of how an evacuation route stays usable. The 300W model at 54,000 lm covers a wide process deck from a single mast position, which keeps the number of fittings — and the number of entries into the classified area — down.
Use Scenarios
- Tank farm perimeter. Mounted on bund walls or dedicated poles and aimed down the walkway between tanks; a 45° or 60° beam keeps the light on the path and off the tank shells, where glare hides the very gauges people are walking out to read.
- Loading gantries and rack ends. The operator needs to see the connection point, the hose and the fall-arrest anchor at the same time. A 60° beam aimed slightly across the bay usually beats a narrow spot aimed straight down the lane.
- Pump and compressor house interiors. Low mounting heights and a lot of pipework call for a 90° or 120° beam at a modest wattage rather than a narrow high-output unit that leaves the rest of the room in shadow.
- Dust-laden bagging and filling halls. Where airborne dust is heavy enough to classify the area, industrial explosion proof lighting mounted above the filling head keeps the operator's work surface lit while the beam stays out of the dust plume itself. This is where LED lighting for manufacturing plants stops being a comfort question and becomes part of the safety case.
- Outdoor yards, rail sidings and truck marshalling areas. Long throws from a mast or a tall wall favour the 25° or 45° option, with the bracket set once and the aim recorded so a replacement goes back to the same angle.
- Turnaround and shutdown positions. Temporary lighting during a maintenance window is easier to plan when the same family covers both the permanent fixtures and the extra units brought in for the duration, so crews are not working from a single fixed source in a space full of scaffolding.
- The same fixture leaves the plant gate and keeps working. Parking lots, plazas, sports and recreation fields, airport aprons, building facades and public parks all suit a bracket-mounted flood with a sealed body and a choice of beam angles — and this explosion proof LED flood light is specified for those jobs on the same terms it is specified for a process area. Outdoors, the 180±10 lm/W build is usually the one worth taking. A 300W unit at that tier delivers 54,000 lm, which is enough for a wide apron or a large car park from a sensible mast height, and the 25° and 45° beams throw that light far enough to keep the pole count down. Where the fixture goes onto a wall or a low column instead, the 60°, 90° and 120° options spread the light without a hot spot at the base. The IP66 and IK08 ratings matter more outside than in. Wind-driven rain finds every seal that is not properly seated, and a car park fixture is exactly the height that a reversing vehicle or a mower can reach. The black powder-coated finish also keeps the fixture from reading as a bright object on a facade. If your project mixes outdoor areas with classified buildings on the same site, one industrial LED lighting solutions package can cover both without two sets of spares, two aiming methods and two documentation trails.
Wattage Range & Light Output
| Power | Luminous flux at 150±10 lm/W | Luminous flux at 180±10 lm/W | Dimensions (mm) | Net weight |
|---|
| 25W | 3750±250 lm | 4500±250 lm | 261×193×126 | 1.7 kg |
| 45W | 6750±450 lm | 8100±450 lm | 261×193×126 | 1.7 kg |
| 75W | 11250±750 lm | 13500±750 lm | 253×289×162 | 2.6 kg |
| 100W | 15000±1000 lm | 18000±1000 lm | 304×289×162 | 3.0 kg |
| 150W | 22500±1500 lm | 27000±1500 lm | 348×289×165 | 3.6 kg |
| 200W | 30000±2000 lm | 36000±2000 lm | 413×360×205 | 5.2 kg |
| 240W | 36000±2400 lm | 43200±2400 lm | 413×360×205 | 5.3 kg |
| 300W | 45000±3000 lm | 54000±3000 lm | 465×360×205 | 6.1 kg |
Product Specifications
| Model No | 3720-25W / 3720-45W / 3720-75W / 3720-100W / 3720-150W / 3720-200W / 3720-240W / 3720-300W |
|---|
| Product dimension | 261*193*126mm / 261*193*126mm / 253*289*162mm / 304*289*162mm / 348*289*165mm / 413*360*205mm / 413*360*205mm / 465*360*205mm |
|---|
| CCT options | 3000K / 4000K / 5000K / 5700K / 6500K |
|---|
| Ingress protection | IP66 / IK08 |
|---|
| Colour rendering index | Ra>80 / Ra>70 |
|---|
| Beam angle | 25° / 45° / 60° / 90° / 120° |
|---|
| Input voltage | 200-277V |
|---|
| Power factor | 0.95 |
|---|
| Frequency | 50/60Hz |
|---|
| Driver type | Constant current |
|---|
| Dimming | 1-10V, optional |
|---|
| Packing information | 2PCS/CTN |
|---|
| Export carton size | 36*23.5*18.5CM / 36*23.5*18.5CM / 36*32.5*18.5CM / 41*32.5*18.5CM / 45.5*32.5*19.5CM / 55*39.5*21.5CM / 55*39.5*21.5CM / 60*39.5*21.5CM |
|---|
| Gross weight | 3.8Kg / 3.8Kg / 5.7Kg / 6.6Kg / 7.8Kg / 11.3Kg / 11.5Kg / 13.2Kg |
|---|
| Material (housing) | Aluminum alloy |
|---|
| Optics | PC + tempered glass |
|---|
| Finish | Powder coating |
|---|
| Fixture colour | Black |
|---|
| Mounting option | Bracket mounting |
|---|
| Storage temperature range | -30°C~+80°C |
|---|
| Storage humidity range | 85% max. |
|---|
| Operating temperature range | -30°C~+45°C |
|---|
| Operating humidity range | 85% max. |
|---|
| Life time | 50,000 hours |
|---|
| Warranty | 5 years |
|---|
| Optional accessories | AC120-277 / 0-10V dimmable / aluminium shading cover / wire guard / CRI>80/90 |
|---|
Options & Accessories
- Aluminium shading cover. Cuts rear spill and glare where the fixture points toward housing, a road or a neighbouring plot, and reduces the complaints that usually end with someone re-aiming the fitting at night.
- Wire guard. Worth adding on explosion proof LED lighting fixtures mounted low enough to meet forklifts, site vehicles or swinging equipment — impact is the most common avoidable failure on a yard installation.
- Higher colour rendering, Ra>80 or Ra>90. For inspection points and colour-critical work, the higher grade makes product and label colours easier to judge under artificial light.
- Surge protection device, listed at 20KV. For masts and exposed yards where lightning and switching surges are a known risk, an SPD at the fitting is cheaper than a lift and a replacement.
- Dimming and control drivers. Dimmable builds are available to suit the control system already on your site, and a 0-10V driver for 120-277V supplies is also offered. Send the interface details with the enquiry so the right driver is quoted first time.
- Accessories quoted with the fixture. Because we work as an industrial LED lighting manufacturer alongside our partner factories, we confirm before release which options are built in and which ship loose in the carton, so nothing arrives that the installing electrician was not expecting.
Installation & Commissioning
- Survey the mounting point first: masonry, structural steel and pole adaptors need different anchors, so mark out the bracket's hole pattern and check the surface behind it before anything is drilled.
- Fix the bracket to the structure, then hang the fixture on the pivot bolt, so nobody is holding the whole weight in the air while they find the thread.
- Bring the supply in through the gland on the underside of the housing and leave a drip loop, which is the cheapest defence against water tracking down a cable into the fitting.
- Aim with the pivot bolt slack: set the throw against the area you actually need lit, check the spill at the boundary or the neighbouring property, then lock the bolt.
- Confirm the front glass and seals are clean and correctly seated, and that the gland is tightened, before the circuit is energised.
- Commission against the schedule: check the colour temperature and output of each position, record the wattage, beam angle and aim at every mounting point, and photograph the installation for the operations and maintenance file.
- Hand over the documentation pack together with the aiming record and accessory list, so the next maintenance window starts from a known baseline instead of from scratch.
Ordering & Delivery
- Sent together, the quotation comes back matched rather than revised. - Options as separate line items. Dimming driver, aluminium shading cover, wire guard, higher colour rendering and surge protection are quoted individually, so you can see what each one adds before deciding. Declarations, test reports and the installation sheet can travel with the goods — tell us the language and format your auditor expects. - Lead time, samples and terms. Lead time depends on wattage, options and order size. Ask your sales contact for the current schedule and about sample availability for approval before a full release.
Testing & Compliance
Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.
- Combustible dust zones. Grain, flour, sugar, starch, wood dust, metal powder and many pharmaceutical powders create classified areas inside otherwise ordinary buildings. The fixture needs to be rated for that dust zone and sealed well enough that dust never reaches the diodes. - Bagging, filling and tipping stations. These are the dustiest points in the building and the ones where an operator is standing still with both hands occupied. Wide distribution at moderate wattage usually reads better here than a narrow beam that leaves the floor around the operator dark. - High mounting in a dusty hall. Where the roof structure sits well above the racking, the 180±10 lm/W build earns its place: the same bracket position delivers enough light to the floor without adding fittings or pulling new circuits. - Responsive light levels. A dimming build lets the circuit follow shift patterns or drop to a holding level in aisles that are locked out overnight, which is where industrial warehouse lighting budgets are usually won or lost. - Stable performance through temperature swings. A loading dock that opens to freezing air on one side and a warm production hall on the other is hard on drivers. Constant-current control keeps output even as the ambient moves. - Continuity for the production team. Lights that stay on and stay aimed mean fewer interruptions in a hall where stopping the line to change a fitting is the expensive part, not the fitting itself.
FAQ
What materials are used in the LED Flood Light 3720 to ensure durability?
The housing is aluminium alloy, finished with powder coating that resists corrosion and rust, and the front is PC plus tempered glass. That combination does three jobs at once: the aluminium carries heat away from the LED board, the powder coat shields the shell from salt and process vapour, and the glass face keeps its clarity under abrasive dust. Sealing is IP66 with IK08 impact protection, so washdown and the occasional knock sit inside the design envelope rather than outside it.
Can you customize the LED Flood Light 3720 for specific industrial applications?
Yes, within the options the platform is built around. You can choose from eight wattages between 25W and 300W, five colour temperatures from 3000K to 6500K, five beam angles from 25° to 120°, and either colour rendering grade. Dimming drivers, an aluminium shading cover, a wire guard and a surge protection device can be added at the point of order. That breadth is what lets an industrial LED lighting manufacturer fit one housing family to a mixed site instead of quoting three separate products. Send the mounting height, the target lux level and the ambient conditions and we will propose the build.
How do you support installation and maintenance?
Orders can include the technical specification sheet and an installation guide covering bracket fixing, gland entry, aiming and the commissioning checks. Because the optical chamber is sealed, routine maintenance is inspection and cleaning rather than lamp changes — wiping the glass and checking bracket and gland tightness after the first storm season is most of the job. A wire guard and a shading cover head off the two most common call-outs, impact damage and glare complaints, before they happen.
How do I confirm the explosion-proof rating matches my zone?
Send us the zone classification, the gas or dust group, the temperature class and the ambient temperature at the mounting position. We will match the model and confirm the rating for that exact configuration before the order is released, because suitability is specific to the individual build rather than to the product family as a whole. If your site works to IEC or NEC classifications, say which, and we will answer in the same terms your safety file uses.
Which colour temperature should I choose?
3000K suits yards and perimeter areas, where warmer light tends to draw fewer complaints from neighbours. 4000K and 5000K are the workhorses for process areas and inspection points, because neutral light makes gauges, labels and leaks easier to read. 5700K and 6500K belong on high masts and large open areas, where the cooler tone reads as brightness at distance. A common split in LED lighting for manufacturing plants is 5000K over production and 4000K on circulation routes, which keeps the two visually distinct at night.