  • LED Flood Light 3720(300W-500W),New-Infinity,LED Flood Light 3720(300W-500W)

LED Flood Light 3720(300W-500W)

High-output outdoor LED flood light for commercial parking lots and large sites in 300-500 W, up to 85,000 lm, IP66 protection and eight beam angles.
Download
View all downloads
  • LED Flood Light 3720(300W-500W),New-Infinity,LED Flood Light 3720(300W-500W)
  • LED Flood Light 3720(300W-500W),New-Infinity,LED Flood Light 3720(300W-500W)
  • LED Flood Light 3720(300W-500W),New-Infinity,LED Flood Light 3720(300W-500W)
  • LED Flood Light 3720(300W-500W),New-Infinity,LED Flood Light 3720(300W-500W)

Description

Product Overview

This is the high-output end of the 3720 flood range: a 300 W, 400 W or 500 W rectangular flood light for the places where light has to carry a long way across open ground — car parks, plazas, sports fields, aprons, quays and building facades. A hinged U-bracket carries the whole head, so aiming happens at the bracket: loosen the locking bolt, tilt, tighten, and the angle stays where you put it. Each wattage is its own model, with its own dimensions and weight, but the three share one bracket design, one driver approach and one set of five colour temperatures. That means a site can put a 500 W at the centre and 300 W at the edges without asking the installation team to learn two different fittings. The optics travel from a 10° pencil beam for facade and high-mast work, through the general 40°, 60° and 90° spreads, to a 120° wash and a 90×120° rectangular pattern for perimeter runs. Most work in commercial LED lighting is retrofit work: an old HID flood comes down, the pole and the circuit stay, and the new fixture has to sit on the same bracket line and reach the same surface. This range is built for that pattern. It is not a hazardous-area fixture — if the site is a classified zone, ask us about our explosion-proof range instead, because the two should never be mixed up on a specification sheet. - One platform across three outputs — the 300 W, 400 W and 500 W models share the same bracket design and driver approach, so a site can mix sizes without mixing installation routines. - Every optic carries its own published output — the 10° and 15° front glasses and the 25°, 40°, 60°, 90°, 120° and 90×120° options each have their own flux figure, instead of one headline number standing in for the whole range. - Sealed for wet and covered positions — the IP66 housing handles rain, jet washing and the damp air of a parking garage LED lighting installation. - Aluminium body with a ribbed back — heat leaves the LED board through the housing itself, which is what keeps output and colour closer to their published values over the years. - Bracket aiming as standard — the hinged U-bracket sets and locks the tilt, so no separate aiming accessory has to be ordered. - Options for exposed positions — 1–10 V dimming, a 20 kV surge device, an aluminium shading cover, a wire guard and higher CRI versions are all available on this platform. - Built with vetted LED lighting manufacturers — we audit the factories behind this range on optical design, thermal management and test documentation, so the numbers hold from batch to batch. - Figures you can actually compare — many LED lighting suppliers quote one wattage and one lumen number; we publish each optic separately, so the figure you compare matches the beam you intend to hang. - Sized for real working areas — from car parks and plazas to LED lighting solutions for warehouse yards, loading lanes and dock aprons.

IP66 and IK08 Protection

IP66 is the rating that matters for an outdoor flood, and it is what to look for on parking lot LED lighting fixtures. The first 6 means the housing is dust-tight; the second 6 means it takes high-pressure water jets from any direction. In service that covers driving rain, sprinkler overspray, jet washing in a service yard and the humid air of a covered deck. It does not cover immersion, and it depends on the cable entry being made off properly with the gland facing down — a fixture that leaves the factory sealed but sits on a pole with an open gland is not IP66 in practice.

IK08 covers impact. The housing and the front optic are rated for the knocks that come with pole-mounted equipment in working areas, from a ladder resting against the head to gravel thrown by a strimmer. It is not a vandal rating for a fixture mounted at ground level in a public square, so where units are within reach, mount them high or add the wire guard.

The operating window runs from −30 °C to +45 °C, with storage between −30 °C and +70 °C, and both operating and storage humidity capped at 85% maximum. That band covers cold winter nights, hot roof decks and the swing between a sunny afternoon and a frosty morning, which is where seals usually fail first. Above the top of the operating range the driver protects itself and output drops, so if you are specifying for a plant-room roof or an enclosed deck, tell us the site conditions and we will confirm the right configuration before you order.

Housing, Finish and Thermal Design

  • Aluminium alloy housing — the LED board is mounted to a metal body that spreads heat away from the emitters instead of letting it collect in one spot.
  • Ribbed heat sink across the back — the fins on the rear give the fixture a large surface to work with, so the LEDs run cooler and hold their output and colour over the years.
  • Powder-coated finish — the coating is there for corrosion and rust resistance, and it resists the chalking that thinner paint shows after a few summers of ultraviolet.
  • PC and tempered glass front — a flat optical front that protects the array, wipes clean and keeps the beam pattern consistent across the face.
  • Flat, slim housing — a low profile keeps the fixture tight to the deck in parking garage LED lighting and reduces wind leverage when it is carried on a pole.
  • Hinged U-bracket and side brackets — the U-bracket carries the tilt, the side brackets hold the head square, and both are part of the housing rather than an optional extra.
  • Matte black as standard — a finish that disappears against pole hardware and facade steelwork instead of drawing the eye.
  • Specified for commercial industrial outdoor lighting duty — the housing is designed around the way these fixtures are actually installed: on poles, on walls and on steelwork, exposed for years at a time.
  • Production we have checked — the housings come from LED lighting manufacturers whose optical, thermal and reliability work we review before a range goes on our list.

Power Range and Coverage

For commercial parking lot LED lighting, the 300 W and 400 W models carry most layouts. The 300 W is the sensible starting point where poles are already closely spaced or the area is a bay row plus its circulation lane. The 400 W is the general-purpose choice for a full car park, a dock apron or a plaza where light has to reach the far kerb without pooling under the pole.

The 500 W is for the jobs where distance and area both grow: sports fields, port quays, airport aprons, large plazas and high-mast positions where the fixture works from the top of a tall pole. Going up a size buys delivered lumens, not just a bigger label — but it also adds physical size and weight to the bracket, so the pole, the arm and the fixings deserve a check before the largest model is specified.

The choice usually comes down to two measurements: how high the fixture will sit, and how much ground one position has to cover. Two 300 W positions on a tighter spacing will often beat one 500 W on a wide spacing, because overlap is what removes dark patches between poles. Send us the pole height, the spacing and the light level you are aiming for, and we will work the layout through with you before you commit to a wattage.

Beam Angles and Configuration

  • 10° — a pencil beam for facades, high-mast accent work and any position where the target is far away and narrow. - 15° — a slightly wider narrow beam for signs, monuments and distant building faces. - 25° — a tighter area distribution for tall poles over a defined zone such as an entrance, a weighbridge or a forecourt. - 40° — the general-purpose area flood, and the usual choice for parking lot LED lighting fixtures over bay rows and circulation lanes. - 60° — a wider general spread for medium mounting heights, where fewer positions have to cover the same ground. - 90° — broad coverage from lower mounting heights: walkways, service yards and building perimeters. - 120° — a very wide wash for close-mounted positions, under-canopy work and parking garage LED lighting where the ceiling is low and the fixture cannot sit far from the floor. - 90×120° — a rectangular spread that suits perimeter runs along a fence line, a wall or a walkway edge. - Colour rendering — Ra>80 and Ra>90 versions are available where the site needs better colour recognition, such as camera coverage or customer-facing plazas. - Getting the optic right matters more than the wattage — the same housing behaves very differently behind a 10° and a 120° front glass, and the cost of a wrong choice appears as dark bays at one site and glare into neighbouring property at another. - Car parks and lots — bay rows, circulation lanes and entrances. For commercial parking lot LED lighting the 300 W and 400 W models cover most layouts, with the 40° or 60° optic doing the bulk of the work. - Plazas and public squares — open areas where light has to reach across without spilling into windows; the 90×120° and 120° optics help keep the pattern where it is wanted. - Sports fields and training grounds — 500 W positions on the mast line, with the narrow optics used where the throw is long. - Airports, aprons and port quays — high-mast positions where the fixture sits far from the surface and the beam has to stay tight. - Building facades — 10° and 15° optics for vertical surfaces, or a wider optic where the wall is close to the pole. - Perimeter and fence lines — the rectangular 90×120° pattern runs light along a boundary instead of pooling it at one end. - Covered decks and parking structures — open-sided decks use the same fixture on wall or soffit brackets, with the wide optics doing the work. - Yards and loading lanes — operators specifying LED lighting solutions for warehouse yards usually want light on the trailer doors and the yard lanes, not on the wall above them.

Efficiency and Running Costs

In commercial industrial outdoor lighting, the electricity bill is the line item that keeps growing, so efficacy is where this range earns its place. The highest-efficacy configuration is the wide-spread Ra>70 version, and that is the one to quote when a project is being compared on lumens per watt. The narrow 10° version sits lower because a tight optic loses more light inside the front glass. Neither figure is a trick — they are the same fixture behind different optics, and the specification section gives the exact numbers for all four configurations.

Against the HID floods this range usually replaces, the gain is large. The platform delivers around 50% more light per watt than the standard products it competes with, which on a big site is the difference between one flood per pole and two, or between a 500 W replacement and a much heavier HID load on the same circuit.

Two details matter to the electrical design. A power factor of 0.95 keeps the current draw down, so cable and breaker sizing stay manageable when a whole car park hangs off one distribution board. And the constant-current driver holds output steady as the supply moves within its band, instead of letting brightness drift with voltage through the evening.

Published efficacy carries a tolerance of ±10 lm/W, and flux carries ±3,000 to ±5,000 lm depending on the model, so compare like with like when you read another sheet. Send us your tariff and running hours and we will work through annual consumption with you.

Electrical and Optical Specifications

Specification300 W / 400 W / 500 W
Model No3720-300W / 3720-400W / 3720-500W
Power300 W / 400 W / 500 W
10° optic, Ra>70 (135 ±10 lm/W)40,500 ±3,000 lm / 54,000 ±4,000 lm / 67,500 ±5,000 lm
15° optic, Ra>70 (150 ±10 lm/W)45,000 ±3,000 lm / 60,000 ±4,000 lm / 75,000 ±5,000 lm
25° / 40° / 60° / 90° / 120° / 90×120° optics, Ra>80 (140 ±10 lm/W)42,000 ±3,000 lm / 56,000 ±4,000 lm / 70,000 ±5,000 lm
25° / 40° / 60° / 90° / 120° / 90×120° optics, Ra>70 (170 ±10 lm/W)51,000 ±3,000 lm / 68,000 ±4,000 lm / 85,000 ±5,000 lm
Beam angle10° / 15° / 25° / 40° / 60° / 90° / 120° / 90×120°
Colour temperature3000 K / 4000 K / 5000 K / 5700 K / 6500 K
Colour rendering indexRa>80 / Ra>70
Input voltage200–277 V
Power factor0.95
Frequency50–60 Hz
Driver typeConstant current
Ingress protection / impact ratingIP66 / IK08
Item300 W / 400 W / 500 W
Product dimension465 × 360 × 67 mm / 479 × 410 × 63 mm / 539 × 410 × 66 mm Net weight
6.8 kg / 8.2 kg / 9 kg Export carton size61 × 45 × 14 cm / 66 × 50 × 14 cm / 71 × 50 × 14 cm Gross weight
8.3 kg / 10 kg / 11.5 kg Packing1 pc per carton Housing
Aluminium alloy OpticsPC + tempered glass Finish
Powder coating Fixture colourBlack Mounting
Bracket mounting Lifetime50,000 hours Dimming
1–10 V (optional)
Efficiency(Ra>70)135±10lm/W (10°)
Efficiency(Ra>80)140±10lm/W (25°/ 40°/ 60°/ 90°/ 120°/90*120°)
Efficiency(Ra>70)150±10lm/W (15°)
Efficiency(Ra>70)170±10lm/W (25°/ 40°/ 60°/ 90°/ 120°/ 90*120°)
Color Rendering IndexRa>80/70
Packing Information1pcs / 1pcs / 1pcs
Export Carton Size61*45*14CM / 66*50*14CM / 71*50*14CM
Storage temperature range-30℃~+70℃
Storage humidity range85% max.
Operating temperature range-30℃~+45℃
Operating humidity range85% max.
Warranty5 Years
Dimmable1-10V Dimmable
Optional AccessoriesAC120-277

Mounting and Aiming

  1. 2. Check that the mounting point — pole arm, wall bracket or steelwork — can carry the fixture and hold it at the working height you have planned.
  2. Fix the bracket first with the hinge slack, so the head can be hung without fighting its own weight.
  3. Hang the head on the bracket and set a rough aim by eye, pointing the face at the target area rather than at the horizon.
  4. Lock the hinge bolt, check the side brackets, then confirm the tilt has not crept under the weight of the head.
  5. Make off the supply cable with the gland facing down and a loop below the entry, so water runs away from the seal instead of into it.
  6. Power up and aim properly after dark — for commercial LED lighting installations the last step is always a night check, walking the area to confirm the pools overlap and that no head is throwing light into neighbouring property.
  7. On LED lighting solutions for warehouse yards, check the aim against the loading lanes and trailer doors as well as the open yard, because a light that suits the yard lane can leave the dock face in shadow.

Maintenance and Annual Inspection

  • Clear the heat sink first — the ribbed back is the fixture's cooling path, so the yearly visit should start by brushing dust, leaf litter and cobwebs out of the fins and confirming nothing has been stacked against the rear or boxed in by cladding added after installation. A blocked heat sink is the quiet cause of fading output and colour shift long before the LEDs themselves are due for replacement.
  • Wash the front, not the seams — the PC and tempered glass face wipes clean with water and a soft cloth; keep abrasive pads, scouring powder and solvent cleaners off the powder coating. A pressure washer aimed at the cable entry will push water past a seal that is doing its job, so wash the optic and let the housing drain.
  • Check the gland and the drip loop every year — the cable entry must still point down with a loop of cable hanging below it. A gland loosened during other works, or a cable that now runs uphill into the entry, is the most common route for water into an IP66 fixture.
  • Re-torque the bracket and re-aim — the hinged U-bracket holds its angle on a locking bolt; check that bolt and the side brackets once a year and after any storm. Tilt creep is slow and easy to miss on a tall pole until the pool of light has visibly walked off the target.
  • Do not open the housing on site — the front seal is set at assembly, and a fixture opened on a pole rarely closes as watertight as it left. Diagnose from the outside and replace the head rather than the gasket.
  • Treat the surge device as a service item — where the 20 kV surge protection option is fitted, fit a new device after a lightning event or a known surge on the circuit instead of assuming the old one still protects the driver.
  • Keep a small spares shelf — a spare head, a spare surge device, a gland and a wire guard get a critical pole back on within a visit instead of waiting on a shipment. Record the model, beam angle, CRI and colour temperature of each installed position so a replacement matches the rest of the array.
  • Store cartons dry before installation — the range is rated for −30 °C to +45 °C in operation and −30 °C to +70 °C in storage at 85% maximum humidity, so keep boxes off damp floors and out of standing water on site.
  • Plan around gradual decline, not sudden failure — the LEDs are rated for 50,000 hours and lose output slowly rather than switching off, so a dusk-to-dawn site will see light soften over the years; checking the layout against the original aim plan at the five-year mark tells you whether to re-lamp a whole pole line at once instead of chasing single heads.
  • Keep records for warranty claims — five years is the stated cover, and a claim moves fastest with the model number, the exact configuration and the installation date to hand.

Ordering and Delivery

  • Order by configuration, not by wattage alone — model, beam angle, CRI and colour temperature together define what arrives; the same wattage in a 10° and a 120° optic are effectively two different products.
  • Tell us the supply — 200–277 V at 50–60 Hz is standard. A site running 120 V needs the alternative driver configuration confirmed before the order is placed.
  • Choose options at the order stage — 1–10 V dimming, the 0–10 V dimmable driver for 120–277 V supplies, aluminium shading cover, wire guard, higher CRI and the 20 kV surge device are all specified per order rather than fitted as standard.
  • Warranty — the range carries a five-year warranty; ask your sales contact how claims are handled in your market and what documentation is required with a claim.
  • Packing — one fixture per export carton, with the carton size and gross weight published for each model so freight and manual handling can be planned.
  • Phased sites — tell us if the lighting is being delivered in stages, so later stages keep the same optic, colour temperature and CRI as the first.
  • Project support — send the pole layout, the target light level and your tariff, and we will work through fixture count, aiming plan and annual consumption for commercial industrial outdoor lighting schemes with you.
  • One schedule, one shipment — if a project also needs high bays, tri-proof fittings or hazardous-area luminaires, we can consolidate the order so the whole schedule arrives together rather than through three separate LED lighting suppliers.
  • Lead time and terms — most of the commercial LED lighting we ship goes out as a project order, so confirm current lead time, payment terms and shipping arrangements with your sales contact; they depend on configuration and destination.

Testing & Compliance

Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.

FAQ

Can these flood lights replace the metal halide or high-pressure sodium fittings already on our site?

Usually yes, and retrofit is the most common way this range is used. For commercial parking lot LED lighting the practical questions are the pole and the circuit rather than the fixture itself: the old ballast or magnetic gear has to be bypassed so the new flood receives a straight mains supply, the bracket or arm has to suit the new housing's fixing points, and the circuit should be checked because the LED load is smaller but draws a different inrush. Aiming changes too — an LED flood puts light exactly where it is pointed, so a head that replaced a large HID unit may need to be set lower, or fitted with a wider optic, to avoid a bright pool directly under the pole. Send us a photo of the existing bracket and gear tray and we will tell you what needs to change.

What colour temperature and colour rendering should we specify?

Five colour temperatures are available, from 3000 K to 6500 K. Most parking lot LED lighting fixtures we ship are ordered at 4000 K or 5000 K, which keeps an area bright without the blue cast that 6500 K gives on a wet surface; 3000 K suits plazas and building settings where a warmer tone sits better with the surroundings, and the higher values are used where cameras need contrast. Colour rendering is a separate decision: Ra>70 is fine for circulation and yard lighting, while Ra>80 and Ra>90 versions are worth the step up where people judge colour on site or where camera footage may be reviewed afterwards.

How do we compare the output figures with quotes from other suppliers?

Compare the configuration, not the wattage. This range publishes four optical and rendering combinations, and the numbers move with them: a narrow 10° front glass delivers less light than the wide optics at the same wattage, and the Ra>80 version sits slightly below the Ra>70 wide version. Every figure also carries a tolerance — ±10 lm/W on efficacy and ±3,000 to ±5,000 lm on flux depending on model. Ask any of the LED lighting suppliers you are comparing to state the beam angle and CRI behind their figure. A quote that gives one lumen number for an entire range is describing its most favorable case, not the optic you are about to install.

What maintenance does the fixture need once it is installed?

Very little beyond inspection. Wipe the front optic and the housing ribs with clean water and a soft cloth when the site cleaning schedule already runs, and keep abrasive pads and solvent cleaners away from the powder coating. Once a year, check that the bracket bolts are tight, that the tilt has not crept, and that the cable gland is intact and still facing down. Do not open the housing in the field — the seal is set at assembly, and a fixture opened on site rarely goes back together as watertight as it left. If a unit does fail, send us the model and configuration and we will work through the cause with you before anything is replaced.

What keeps the light output steady over the life of the fixture?

Two things: the driver and the thermal path. The driver is constant current, so output stays level as the supply moves within its band instead of dimming with voltage, and a power factor of 0.95 keeps the load clean on a busy distribution board. Behind that, the LED board sits on an aluminium housing with a ribbed back, which is what stops heat building up in the emitters — and heat is what makes LEDs lose output and shift colour over time. The rated life for the range is 50,000 hours, which is a module rating rather than a switch-off point; output declines gradually rather than stopping. The LED lighting manufacturers behind this range are reviewed on that pairing, thermal design and driver choice together, because either one alone is only half the answer.