200 lm/W T8 LED Tube Light - commercial LED lighting
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W

LED Tube Light - T8 Series 200 lm/W Ultra High Efficacy - New-Infinity

A 200 lm/W G13 LED tube light for commercial retrofits, available in multiple wattages and color temperatures for warehouse and office upgrades.
Download
View all downloads
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W
  • VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W,MY SHOP,VIS-T8 Series LED Tube Light – Ultra High Efficacy 200 lm/W

Description

Product Overview

The VIS-T8 Series is a T8 LED tube light built for lighting upgrades in occupied commercial buildings — sites where the fixtures are already in the ceiling and the only thing that has to change is the tube inside them. It fits G13 holders, comes in three standard body lengths and is supplied in five power steps, so one tube family can serve a corridor, a classroom and a warehouse aisle from a single order.

The range runs from 4 W to 15 W and from 800 lm to 3000 lm, with each wattage paired to its own lumen output rather than squeezed out of a single high-output tube. Every tube is specified to match or beat the output of a fluorescent between 10 W and 40 W, which is what makes the swap like-for-like in light and far smaller in watts. Colour temperature is selectable between 3000 K and 6500 K, and the cover is available in a striped or milky white finish.

We supply this tube for commercial led tube lighting projects across warehouses, factories, supermarkets, offices, schools, car parks and hospitals — retrofit work where the brief is usually the same: hold the light level, cut the bill, and keep the building running while you do it. It is the smallest item in most led lighting retrofit solutions we put together for a plant, and usually the first one to pay for itself. Color temperature options are 3000K, 4000K, 5000K and 6500K, with customization available on request.

T8 Tube Advantages

  • Direct replacement on G13, no rewiring — the tube goes into the holder the fluorescent came out of, leaving the fixture, reflector and ceiling fixing untouched. That removes the electrician, the permit-to-work and the ceiling access a fixture change would need. Against fluorescent, the same light costs 60–70% less energy. - A driver that does not flicker — output stays steady, with no visible ripple at the edge of vision and no stroboscopic effect around rotating machinery. That matters in workshops and in any room where people work a full shift under the light. - Non-glass, shatter-resistant body — engineering plastic instead of glass, so an impact overhead leaves a dented tube rather than glass on the floor. This is why the tube is chosen for food, pharmaceutical and packaging areas, where a breakage is a contamination incident rather than a cleanup. Output falls gradually across the rated life instead of dropping off a cliff, so the installation holds its design level rather than fading out of compliance.

Installation and Commissioning

  1. Isolate the lighting circuit at the distribution board and prove the fixture is dead before you touch the tube.
  2. Check that the holders are G13 bi-pin and undamaged. Cracked or heat-brittled holders are the usual reason a new tube sits loose, and they are worth replacing before the tube goes in.
  3. Take out the old fluorescent tube. On a standard G13 led tube light fixture nothing else changes — the new tube goes into the same holders.
  4. Line the pins up with the holder slots, push the tube in and twist a quarter turn until it seats. Do not force it: a tube that will not seat is usually the wrong length or a damaged holder.
  5. Restore power and check the run — steady output, no flicker, and the same colour from tube to tube along the row.
  6. Work a whole row in one pass rather than mixing old and new tubes, so any difference in brightness is not left half-way down an aisle.
  7. Note the tube length, wattage and fitting type on the panel schedule; the next re-order then becomes a one-line instruction instead of another site survey.
  8. If a tube flickers, a row trips or the colour does not match the sample, stop and send our technical team the fixture type, the tube length and a photo of the installation.

Applications

  • Warehouses and distribution centres — long rows of fittings above racking aisles, where led warehouse lighting has to keep up with shifts that run around the clock.
  • Factories and production halls — assembly, machine and packing areas where tubes sit above workbenches and take the occasional knock from a ladder, a trolley or a box of stock.
  • Supermarkets and store floors — continuous runs over shelving and chilled cabinets, where the diffused light keeps product faces even instead of dropping a bright spot over every shelf.
  • Parking garages and service areas — low ceilings, long sight lines and lighting that stays on all night; the wide spread through the diffuser cuts the dark corners drivers misjudge.
  • Hospitals, clinics and cleanrooms — corridors, waiting areas and support rooms where light has to stay steady for staff on long shifts and every maintenance visit is disruptive.
  • Offices, schools and training rooms — open-plan desks, classrooms and study areas where the tube sits in the sightline for most of the working day.
  • Anywhere a G13 fluorescent tube sits in a dry indoor space — if the fitting takes a bi-pin tube and the room is dry, the tube is a direct candidate, which makes it one of the simplest led lighting retrofit solutions available for a building that is already lit.
  • Offices, classrooms and training rooms are judged on comfort rather than output, and the complaints that come back after a lighting change are almost always about flicker, glare or colour — the three things this tube was specified around. Flicker is the complaint people cannot name. A tube that ripples at mains frequency produces headaches, eye strain and a flat feeling at the end of an afternoon in a windowless room. The driver holds output steady, which is why the tube suits rooms with full-day occupancy rather than corridors and cupboards. Light on the desk, not in the eyes. Sitting under a bare tube is uncomfortable, and the higher the ceiling the worse the glare angle. The diffused 120° output spreads light across the ceiling and back down the room so the source stays out of a sightline; milky white covers are the usual choice for open-plan space for exactly this reason. One colour temperature per floor. Printed handouts, whiteboard work, samples and screens all depend on the light being predictable. Fixing one colour temperature across a floor, and storing the spares labelled with it, prevents the patchwork look that follows a retrofit done in stages. A job the site team can run themselves. Schools and office buildings usually have caretaking staff on site and long holidays in the calendar. Because nothing below the tube changes, a building can be re-lamped between terms without a contractor, scaffolding or an electrical alteration — a practical route for a facilities team working through led lighting retrofit solutions one building at a time. Where the numbers add up. An office or a school has hundreds of tube positions lit for eight to ten hours a day across a long year. The saving per tube is modest; the count is what makes it worth doing, and the count is also what makes commercial led lighting budgets work in these buildings.
Linear LED tube fixtures installed in retail, office, parking and food-processing interiors

Specifications

ParameterValue
ModelT8
Power4W / 6W / 9W / 12W / 15W
Luminous flux800 lm / 1200 lm / 1800 lm / 2400 lm / 3000 lm
Luminous efficacy200 lm/W
Colour temperature3000 K / 4000 K / 5000 K / 6500 K (customizable)
Colour rendering index (CRI)Ra > 75
Beam angle120°
Cover typeStriped / Milky white
BaseG13
Body length600 mm / 1200 mm / 1500 mm (custom lengths on request)

Electrical and Operating Data

ParameterValue
Input voltageAC 100–277V (50/60Hz) – universal voltage
Power factor>0.95
Driver efficiency>96%
Total harmonic distortionTHD
EMI complianceEN55015
LED configuration3V / 60mA chips
Housing materialEngineering plastic (non-glass)
Operating temperature-20°C to +60°C
IP ratingIP20 (indoor use)
Lifetime>50,000 hours
Warranty3 years (5 years optional)

Wattage and Length Selection

  • Measure the tube you are replacing first — length is taken end cap to end cap, with the pins excluded. - Choose output against mounting height, not floor area — 4 W / 800 lm for cupboards, small stores and single-tube corridors; 6 W / 1200 lm for low-ceiling runs; 9 W / 1800 lm as the general step for office and classroom rows; 12 W / 2400 lm and 15 W / 3000 lm for taller industrial space and racking aisles where the fitting sits well above head height. - Count tubes, not fixtures — a twin-tube led tube light fixture takes two tubes of the same length, and it is worth checking that the second position is live before the full count is ordered. - Keep one wattage along a run — mixing outputs in a single row leaves bright and dim patches in the led tube lighting that no diffuser hides, and it complicates the next re-order. - Choose the cover for the room — milky white where the tube sits in a direct sightline and you want a fully diffused face; striped where the fitting is louvred or recessed and a little more output through the cover is welcome. - Test one position before committing — fit a single tube in the spot people already complain about. It settles the wattage question faster than any calculation on paper.

Ordering and Project Support

  1. Send the tube length, the wattage and the number of positions for each area. Where a length falls between the three standard sizes, include the measurement and we will quote a custom build.
  2. Confirm the colour temperature and cover type per area, so the quotation matches what the installer will actually fit.
  3. Say whether the project needs the extended warranty option rather than the standard cover — it is easier to build in at quotation than to add afterwards.
  4. Ask your sales contact about sample availability and timing if you want to test one position before the full order. 5.
  5. Set the delivery schedule against your installation plan. A staged retrofit works most reliably when the tubes arrive in the same phases as the aisles or floors being changed — the usual pattern for led lighting retrofit solutions across a live site.
  6. Order the spares with the first batch. Tubes from a later production run can differ slightly in colour, and a store-room spare removes that risk.
  7. If your sites run on different supply voltages, note it on the order; the universal input covers the range, but labels and paperwork still have to match each site.
  8. Tell us if the tubes are one part of a wider led lighting solutions package for the building, so deliveries can be sequenced and the tube swap does not land on site at the same time as the panel or outdoor work.

Testing & Compliance

Every product we supply is CE and RoHS compliant, and we can send the matching declarations and test documentation with your order, so your safety, quality and brand audits have something concrete to check. Working through a network of certified partner suppliers, we verify each batch before it ships: current certificate version, label matching the report, and documents in the language your auditor expects. Tell us the standard your project is measured against and we will confirm what we can provide before you commit.

The warehouse is usually where a commercial led tube lighting project pays back fastest. The lights run for most of the day, sometimes around the clock, and the fixtures are already in the ceiling — so changing what sits inside them is quicker, cheaper and far less disruptive than changing the fixtures themselves. Working at height without closing the aisle. Nothing below the tube changes, so a maintenance team can bring a scissor lift into one aisle, work along that run and move to the next. There is no second visit for wiring, no new housings delivered to site and no skip filled with old fittings. On a site that cannot stop, that is often the difference between a project that happens this quarter and one that keeps being postponed. Phasing the changeover. Because the unit of work is a single tube, led warehouse lighting can be rolled out aisle by aisle or building by building, with the saving starting from the first run rather than after the last one. Light where the work actually is. Reading a label or finding the edge of a pallet needs light on the rack face, not just on the floor. The 120° beam through the diffuser spreads light sideways as well as down, so upper rack levels stay readable instead of falling into shadow between rows. Less heat rejected into the space. A fluorescent tube puts a noticeable share of its power into heat; an LED tube does not. In chilled or temperature-controlled storage that shows up as reduced load on the refrigeration plant as well as on the lighting circuit. One batch, one colour. Order the full site quantity in one go and keep a spare set from the same batch. Tubes from a single production run match each other across aisles, and a later failure becomes a like-for-like swap instead of a visible mismatch. Record the baseline before you start. Note the wattage and the count of the tubes coming out. That one number lets your finance team check the saving against the next electricity bill rather than taking it on trust.

FAQ

Can you customize the power and length options for the led tube light fixture?

Yes. The standard build covers 4 W, 6 W, 9 W, 12 W and 15 W across the three body lengths, and we quote custom sizes when an existing led tube light fixture sits between them. Send the measurement of the tube you are replacing — end cap to end cap, pins excluded — together with the wattage and the quantity for each length, and we will confirm whether a standard build or a custom T8 LED tube light is the better answer. Colour temperature and cover type can be fixed in the same conversation, so one order can cover a whole site even where different areas need different outputs.

What safety and durability features do these LED tubes offer?

The body is engineering plastic rather than glass, so there is no shatter risk over a production line or a shop floor, and there is no mercury inside to deal with if a tube is knocked out of a holder. Electrically, the design targets a power factor above 0.95 and meets EN55015 for electromagnetic compatibility, so the tube does not disturb nearby equipment. It is rated from -20 °C to +60 °C, which covers unheated stores and roof voids, and the housing stays rigid rather than going brittle when a building cools down overnight.

How do your LED tube lighting solutions improve energy efficiency compared to fluorescent tubes?

The gain comes from efficacy. At 200 lm/W the tube produces the light of a fluorescent from a fraction of the power, and in practice a scheme switched from fluorescent to commercial led tube lighting uses 60–70% less electricity for the same illuminance. Driver efficiency above 96% and power factor above 0.95 mean very little is lost before the power reaches the LEDs, and the total harmonic distortion figure on the datasheet lets your electrical team check it against their own limits. Where the lights run around the clock — led warehouse lighting being the obvious case — the saving compounds quickly.

Do you provide support for installation and troubleshooting of your LED tube lights?

Yes. Every order comes with fitting guidance for a standard G13 retrofit, and our technical team will work through anything that is not standard — a fitting we have not seen before, a run that trips, a colour that does not match the sample. Send the fixture type, the tube length and a photo of the installation and we will come back with an answer. If you are planning led tube lighting across several buildings, we can review the layout and the counts with you before the order rather than after it.

Can these tubes be used outdoors or in wet areas?

No. This is an IP20 tube for dry indoor locations: plant rooms, production areas and covered car parks are fine, but open canopies, wash-down bays and cold rooms with heavy condensation need a sealed fitting instead. Outdoor and wet environments are a different class of commercial led lighting product, and an indoor tube used there will not last and sits outside its rating. Tell us the environment and we will point you to the right body.

Which colour temperature should I choose?

Match it to the work rather than to the catalogue. 3000 K reads warm and suits reception areas, break rooms and hospitality space; 4000 K is the neutral default for offices, classrooms and meeting rooms; 5000 K and 6500 K give the crisp, bright feel usually wanted over racking, production lines and inspection points. Mixing values in one open space rarely looks deliberate, so fix the colour per zone before ordering. Where a project spans several areas, planning colour temperature zone by zone at quotation stage means the led lighting solutions you receive match the rooms they are going into.